The largest database of trusted experimental protocols

6 protocols using zomepirac sodium salt

1

Characterization of Biological Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Purified water was obtained by using a Milli-Q Integral 3 system (Millipore SAS, Molsheim, France). Zomepirac sodium salt (used as internal standard, IS), L-pyroglutamic acid, hypoxanthine, L-histidine monohydrochloride monohydrate, oleic acid, L(+) lactic acid, LS-MS grade acetonitrile, methanol, formic acid, and LC grade ethanol were purchased from Sigma-Aldrich Chemie GmbH (Steinheim, Germany). The API-TOF reference mass solution kit (G1969-850001) and tuning solutions, ESI-L low-concentration tuning mix (G1969-85000), and ESI-TOF Biopolymer Analysis reference masses (G1969-850003) were purchased from Agilent Technologies (Santa Clara, CA, USA).
+ Open protocol
+ Expand
2

Preparation of Aqueous Solutions

Check if the same lab product or an alternative is used in the 5 most similar protocols
Ultrapure water was used to prepare all the aqueous solutions and was obtained “in-house” from a Milli-Q Integral three system (Millipore, SAS, Molsheim, France). Zomepirac sodium salt, formic acid, LC-MS-grade methanol and acetonitrile, and LC-grade ethanol were purchased from Sigma-Aldrich Chemie GmbH (Steinheim, Germany).
+ Open protocol
+ Expand
3

Quantitative Lipidomic Analysis Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blank samples included mixtures of methanol/ethanol (1:1) that were prepared in the same way as biological samples. Zomepirac sodium salt (used as the internal standard (IS), arachidonic acid, docosahexaenoic acid, lysophosphatidylethanolamine (LPE) 18:0, phosphatidylethanolamine (PE) 16:0/22:6, LS-MS-grade acetonitrile, methanol, LC-grade formic acid, and ethanol were purchased from Sigma-Aldrich Chemie GmbH (Steinheim, Germany). The API-TOF reference mass solution kit (G1969-850001) and tuning solutions, ESI-L low-concentration tuning mix (G1969-85000), and ESI-TOF Biopolymer Analysis reference masses (G1969-850003) were purchased from Agilent Technologies (Santa Clara, CA, United States). Purified water was obtained using the Milli-Q Integral three system (Millipore SAS, Molsheim, France) in order to prepare solution A.
+ Open protocol
+ Expand
4

Ultrapure Water Preparation for Analytical Experiments

Check if the same lab product or an alternative is used in the 5 most similar protocols
Ultrapure water was used to prepare all aqueous solutions and was obtained using a Milli-Q Integral 3 system (MilliporeSigma, Burlington, MA, United States). Zomepirac sodium salt, formic acid, LC-MS-grade methanol, acetonitrile, and LC-grade ethanol were purchased from Sigma-Aldrich (St. Louis, MO, United States).
+ Open protocol
+ Expand
5

Mass Spectrometry Protocol for Metabolite Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Purified water was obtained using the Milli-Q Integral 3 system (Millipore SAS, Molsheim, France). Zomepirac sodium salt (used as an internal standard, IS), L-serine, L-arginine hydrochloride monohydrate, ascorbic acid, L-homoarginine hydrochloride, LC-MS grade methanol acetonitrile, formic acid and LC grade ethanol were purchased from Sigma-Aldrich Chemie GmbH (Steinheim, Germany). Pure p. a. ammonium solution (25%) was purchased from Avantor Performance Materials (Gliwice, Poland). The API-TOF reference mass solution kit (G1969–850001) and tuning solutions, ESI-L low concentration tuning mix (G1969–85000) and ESI-TOF Biopolymer Analysis reference masses (G1969–850003) were purchased from Agilent Technologies (Santa Clara, California, United States).
+ Open protocol
+ Expand
6

Mass Spectrometry Protocol Optimization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Purified water was obtained using the Milli-Q Integral 3 system (Millipore SAS, Molsheim, France). Zomepirac sodium salt (used as internal standard, IS), LS-MS-grade acetonitrile (ACN), methanol (MeOH), and formic acid (FA) were purchased from Sigma-Aldrich Chemie GmbH (Steinheim, Germany). Pure p.a. ammonium solution (25%) was purchased from Avantor Performance Materials (Gliwice, Poland). The API-TOF reference mass solution kit (G1969-850001) and tuning solutions, ESI-L low concentration tuning mix (G1969-85000), and ESI-TOF Biopolymer Analysis reference masses (G1969-850003) were purchased from Agilent Technologies (Santa Clara, CA, USA). Standards to confirm the identity of metabolites were purchased from Sigma-Aldrich Chemie GmbH (Steinheim, Germany) (taurine, pipecolic acid, leucine, histidine, phenylalanine, 3-methylhistidine, citric acid, tryptophan, adenosine, and stearoylcarnitine) and Avanti Polar Lipids Inc. (AL, USA) (LPI 18:0 and LPG 18:1).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!