The largest database of trusted experimental protocols

Agilent 6520 accurate mass q tof lc

Manufactured by Agilent Technologies

The Agilent 6520 Accurate-Mass Q-TOF LC is a high-resolution, accurate-mass liquid chromatography-quadrupole time-of-flight mass spectrometer. It is designed to provide high-quality data for a variety of analytical applications.

Automatically generated - may contain errors

2 protocols using agilent 6520 accurate mass q tof lc

1

Spectroscopic Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were measured on a JASCO P-2000 automatic digital polarimeter. UV and CD spectra were recorded on a JASCO-815 CD spectrometer. IR spectra were measured on a Nicolet 5700 FT-IR microscope instrument (FT-IR microscope transmission). NMR spectra were obtained at 600 MHz for 1H and 150 MHz for 13C, respectively, on a Bruker AVIIIHD 600 NMR spectrometer. ESIMS and HRESIMS data were measured using AB SCIEX QTOF MS (QSTAR Elite) and Agilent 6520 Accurate-Mass Q-TOF LC/MS spectrometers, respectively. Analytical HPLC was conducted on an Agilent 1260 infinity system equipped with a DAD-UV detector. Preparative HPLC was performed on a CXTH system (Beijing Chuangxintongheng instrument Co. Ltd., P.R. China), equipped with a UV3000 detector using a YMC-Pack ODS-A column (250 × 20 mm, 5 μm, Kyoto, Japan). Preparative TLC were performed on precoated TLC plates (400-500 μm thickness, HSGF254, Yantai Jiangyou Silica Gel Development Co. Ltd., Yantai, P.R. China). Polyamide (30–60 mesh, Changzhou Changfeng Chemical Factory, China), Silica gel (100–200, 200–300 mesh, Qingdao Marin Chemical Inc. Qingdao, P.R. China) and Sephadex LH-20 (GE), and ODS (50 μm, YMC, Japan) were used for column chromatography.
+ Open protocol
+ Expand
2

LC-ESI/MS Analysis of Catechin Fraction

Check if the same lab product or an alternative is used in the 5 most similar protocols
LC-ESI/MS analysis of catechin fraction was conducted on Agilent 6520 accurate mass Q-TOF LC/MS coupled with Agilent LC 1200 equipped with Extend-C18 column of 1.8 μm, 2.1 × 50 mm. Gradient elution was performed with LC/MS grade acetonitrile (A) and 0.1% acetic acid in methanol (B) at a constant flow rate of 0.7 ml/min, with an increase in the volume of B %: 5-20%, 12-30%, 19-40%, 26-50%, and 30-40%. The MS analysis was performed using ESI in negative mode with the following conditions: drying gas (nitrogen) flow 5 L/min, nebulizer pressure 40 psig, drying gas temperature 325 °C, capillary voltage + 3000 V, fragmentor volt 125 V, and Oct RF Vpp 750 V. The mass fragmentation was performed with varying collision energy 4 V/100 DA with an offset of 8 V.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!