Ionpac as11 hc 4 μm rfic hpic

Manufactured by Thermo Fisher Scientific

The IonPac AS11-HC-4 μm RFIC&HPIC is a high-performance ion chromatography column designed for the separation and analysis of inorganic anions. It features a 4-micron particle size and is compatible with Reagent-Free Ion Chromatography (RFIC) and High-Performance Ion Chromatography (HPIC) systems.

Automatically generated - may contain errors

3 protocols using ionpac as11 hc 4 μm rfic hpic

1

IC-UHR-FTMS for Metabolite Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
Ion chromatography-ultra high-resolution-Fourier transform-MS (IC-UHR-FTMS) was performed as previously described (52 ). Briefly, polar extracts were reconstituted in 20 μL Nanopure water, and analyzed by a Dionex ICS-5000+ ion chromatograph interfaced to an Orbitrap Fusion Tribrid mass spectrometer (Thermo Fisher Scientific, San Jose, CA, USA) operating at a resolution setting of 500,000 (FWHM at m/z 200) on MS1 acquisition to capture all 13C isotopologues. The chromatograph was outfitted with a Dionex IonPac AG11-HC-4 μm RFIC&HPIC (2 × 50 mm) guard column upstream of a Dionex IonPac AS11-HC-4 μm RFIC&HPIC (2 × 250 mm) column. Chromatography and mass spectrometric settings were the same as described previously (60 ) with an m/z range of 80 to 700. Metabolites and their isotopologues were identified and their peak areas were integrated and exported to Excel via the TraceFinder 3.3 (Thermo) software package. Peak areas were corrected for natural abundance as previously described (62 (link)), after which fractional enrichment and μmoles metabolites/g protein were calculated to quantify 13C incorporation into various metabolites.
+ Open protocol
+ Expand
2

High-Resolution Isotopic Analysis of UDP-GlcNAc

Check if the same lab product or an alternative is used in the 5 most similar protocols
Polar fractions were reconstituted in 30 μL nanopure water, and analyzed on a Dionex ICS-5000+ion chromatograph interfaced to an Orbitrap Fusion Tribrid mass spectrometer (Thermo Fisher Scientific, San Jose, CA, USA) operating at a resolution setting of 500,000 (FWHM at m/z 200) on MS1 acquisition to capture any and all 13C isotopologues. The Orbitrap Fusion was tuned and calibrated according to the manufacturer’s default standard recommendations, to routinely achieve a mass accuracy of 0.5 ppm or better. The chromatograph was outfitted with a Dionex IonPac AG11-HC-4 μm RFIC&HPIC guard (2 × 50 mm) guard column upstream of a Dionex IonPac AS11-HC-4 μm RFIC&HPIC (2 × 250 mm) column. An m/z range of 80–700 except for the organ extracts where the m/z range was 50-750. Peak areas were integrated and exported to Excel via the TraceFinder 3.3 (Themo) software package. Peak areas were corrected for natural abundance distribution of each of the isotopologues, after which fractional enrichment were calculated to quantify 13C incorporation into UDP-GlcNAc.
+ Open protocol
+ Expand
3

Ion Chromatography-MS for Metabolite Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Ion chromatography- Fourier transform-MS was performed as previously described [33 (link)]. Briefly, polar extracts were reconstituted in 20 μL nanopure water, and analyzed by a Dionex ICS-5000+ ion chromatograph interfaced to an Orbitrap Fusion Tribrid mass spectrometer (Thermo Fisher Scientific, San Jose, CA, USA) operating at a resolution setting of 500,000 (FWHM at m/z 200) on MS1 acquisition to capture all 13C isotopologues. The chromatography was performed using a Dionex IonPac AG11-HC-4 μm RFIC&HPIC (2 × 50 mm) guard column upstream of a Dionex IonPac AS11-HC-4 μm RFIC&HPIC (2 × 250 mm) column. Chromatography and mass spectrometric settings were the same as described previously [31 ] with an acquisition m/z range of 80 to 700. Metabolites and their isotopologues were identified by chromatographic retention times and their m/z values compared with those of the standards. Peak were integrated and the areas exported to Excel via the TraceFinder 3.3 (Thermo, Waltham, MA, USA) software package. Peak areas were corrected for natural abundance as previously described [34 ], after which fractional enrichment and μmoles metabolites/g protein were calculated to quantify 13C incorporation into various metabolites.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!