1

Metabolite Profiling of Cell Culture Media

Check if the same lab product or an alternative is used in the 5 most similar protocols
10 μL of extracted cultured media were separated using a
150 × 2.0 mm Luna NH2 column (Phenomenex); mobile phase A: 20mM
ammonium acetate, 20mM ammonium hydroxide in water; mobile phase B: l0mM
ammonium hydroxide in 10% water/22.5% methanol/67.5% acetonitrile. The
column was eluted isocratically with a linear gradient from 100% to 0%
mobile phase B over 10 minutes, then 2 minutes at 0% mobile phase B. MS
data were acquired with multiple reaction monitoring in the negative ion
mode on a TSQ Quantiva triple quadrupole MS (Thermo Fisher Scientific).
Raw data were integrated and visually inspected using TraceFinder 2.1
software (Thermo Fisher Scientific). MRM transitions were as follows:
pyruvate (87/43), lactate (89.1/43.1), lactate-d3 (92.1/45.1).
Metabolite identifications were confirmed using synthetic mixtures of
reference compounds.
+ Open protocol
+ Expand
2

Multimodal Metabolite Profiling of Tissues

Check if the same lab product or an alternative is used in the 5 most similar protocols
Metabolites in the serum, liver, and muscle tissues collected from the studied rats were profiled by performing UPLC-MS analysis. Briefly, the liver and muscle samples were homogenized completely and centrifuged to generate supernatant. The resulting clear supernatant of the serum, liver, and muscle samples was transferred into the UPLC vials. Prior to examination of the experimental samples, quality controls were run to stabilize the HPLC equipment. For screening on untargeted metabolites, in positive mode, Atlantis HILIC Silica column (Waters, USA) was used; in negative mode, a BEH Amide column (Waters, USA) was used for metabolites separation. The MS methods were conducted on Q Extract Orbitrap MS screening according to the manufacturer's manual. To screen the targeted metabolites, Synergi Hydro-RP 100A column (Phenomenex, USA) and TSQ Quantiva Triple Quadrupole MS (Thermo Fisher, CA) with positive/ negative ion switching were used.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!