Nicolet nexus 6700 spectrometer

Manufactured by Thermo Fisher Scientific
Sourced in France, United States

The Nicolet Nexus 6700 spectrometer is a versatile laboratory instrument designed for spectroscopic analysis. It features a high-resolution optical system and advanced electronics to capture and process spectral data.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using nicolet nexus 6700 spectrometer

1

Characterization of Essential Oil Spectra

Check if the same lab product or an alternative is used in the 5 most similar protocols
The infrared spectra of clove and spearmint EOs, major EO compounds and raw matrices were characterized using a FTIR Nicolet Nexus 6700 spectrometer (Thermo Scientific, Courtaboeuf, France) in attenuated total reflection mode, equipped with a Mercury-Cadmium-Telluride High D detector and using the Omnic v7.3 software (Thermo electron). The spectra of major compounds of both EOs were obtained by deposing around 13 mg of the standard components over the diamond crystal (Ø = 2 mm) of a Smart DuraSamplIR accessory (Thermo Scientific, U.K.). Spectral data were collected at room temperature and accumulated from 64 scans with a resolution of 2 cm-1 in the range of 800 to 4000 cm-1. A correction was applied by subtracting the background spectrum of air. The matrices with a known amount of EO were grinded using a laboratory mortar until a fine powder was reached. Then, the powder was directly analyzed by the ATR-FTIR using the same procedure described above. The crystal was cleaned between measurements with ethanol and dried with a lint-free tissue. For each sample, three or four spectral data were performed. Then, for the calibration curve of clove EO produced from 9 concentrations by triplicate, 108 (N = 4 x 9 x 3) spectral data were acquired. For spearmint EO, 54 (N = 3 x 6 x 3) spectral data were taken.
+ Open protocol
+ Expand
2

Synthesis and Characterization of SPI-CH

Check if the same lab product or an alternative is used in the 5 most similar protocols
The synthesis of SPI-CH was confirmed by nuclear resonance (1H NMR, JEOL ECS, Tokyo, Japan, 400 MHz) spectra and UV-Vis spectrophotometry (TU-1901, Purkinje General Instrument Co., Ltd., Beijing, China). The HCA, SPI, and SPI-CH samples were dried and dissolved into DMSO-d6. Attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectra of SPI-CH conjugates was recorded using a Nicolet Nexus 6700 spectrometer (Thermo Scientific, Madison, WI, USA) from 4000 to 650 cm−1 wavenumbers with 32 scans.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!