Unity inova ddr spectrometer

Manufactured by Agilent Technologies

The Unity Inova DDR spectrometer is a laboratory instrument designed for nuclear magnetic resonance (NMR) spectroscopy. It is capable of performing double-resonance experiments, which allow for the analysis of chemical structures and molecular interactions.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using unity inova ddr spectrometer

1

NMR Spectroscopy of Aqueous Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
NMR spectra
were recorded on a Varian Unity Inova DDR spectrometer
(599.9 MHz for 1H) with a 5 mm 1H{13C/31P–15N} pulse field gradient triple
resonance probe head at 298.15 ± 0.1 K. The solvent was H2O/D2O 95:5 (V/V), and the ionic strength was adjusted
to 0.15 mol/L with KCl. The pH values were adjusted with HCl or NaOH
and determined in situ by internal indicator molecules (having ca.
1 mmol/L concentration) optimized for 1H NMR.25 (link),26 (link) The sample volume was 550 μL (containing ca. 5 mmol/L titrand
substance), and every sample contained ca. 1 mmol/L DSS (3-(trimethylsilyl)propane-1-sulfonate)
as chemical shift reference. The H2O 1H signal
was suppressed with a presaturation sequence; the average acquisition
parameters for 1H measurements are number of transients
= 16, number of points = 65 536, acquisition time = 3.33 s, and
relaxation delay = 1.5 s.
+ Open protocol
+ Expand
2

NMR Spectroscopy of Biomolecules in Aqueous Solutions

Check if the same lab product or an alternative is used in the 5 most similar protocols
NMR spectra were recorded on a Varian Unity Inova DDR spectrometer (599.9 MHz for 1H) with a 5 mm 1H{13C/31P-15N} pulse field gradient triple resonance probehead at 298.15 ± 0.1 K. The solvent was H2O:D2O 95:5 (V/V), ionic strength was adjusted to 0.15 mol/L with KCl. The pH values were adjusted with HCl or NaOH and determined in situ by internal indicator molecules (at ca. 1 mmol/L) optimized for 1H NMR [11 , 12 (link)]. The sample volume was 550 μL and every sample contained ca. 1 mmol/L DSS (3-(trimethylsilyl) propane-1-sulfonate) as chemical shift reference. The H2O 1H signal was suppressed with a presaturation sequence; the average acquisition parameters for 1H measurements are: number of transients = 16, number of points = 65536, acquisition time = 3.33 s, relaxation delay = 1.5 s. 1H-13C HSQC measurements were performed with solvent signal presaturation and the following parameters: number of transients = 64, number of increments = 96, number of points = 2884, acquisition time = 149.968 ms, relaxation delay = 1 s.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.