The largest database of trusted experimental protocols

3 protocols using slug rabbit mab

1

Western Blot Analysis of EMT Markers

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cells were lysed with lysis buffer radioimmunoprecipitation assay (RIPA) (Beyotime Institute of Biotechnology, China) and a mixture of protease inhibitors phenylmethanesulfonyl fluoride (PMSF) (Beyotime Institute of Biotechnology, China). The protein concentration was estimated by bicinchoninic acid (BCA) protein assay kit (Beyotime Institute of Biotechnology, China). Equal amounts of protein were separated on sodium dodecyl sulfate–polyacrylamide gel electrophoresis (SDS-PAGE). After being transferred to polyvinylidene difluoride (PVDF) membranes (Millipore, USA), membranes were blocked with 5 % non-fat milk and then incubated with primary antibodies at 4 °C overnight. Secondary antibodies were incubated for 2 h at room temperature. Protein bands were visualized using the enhanced chemiluminescence detection kit (Thermo scientific, USA). The primary antibodies were: CNTN-1 mAb (1:1000, Abcam, UK), E-cadherin rabbit mAb (1:1000, Cell Signaling Technology, USA), Slug rabbit mAb (1:1000, Cell Signaling Technology, USA), Snail rabbit pAb (1:1000, Abcam, UK), N-cadherin rabbit mAb (1:1000, Cell Signaling Technology, USA) and GAPDH mAb-HRP (1:5000, Bioworld Technology, USA).
+ Open protocol
+ Expand
2

Western Blot Analysis of Epithelial-Mesenchymal Transition

Check if the same lab product or an alternative is used in the 5 most similar protocols
The cells were lysed with radioimmunoprecipitation assay (RIPA) lysis buffer supplemented with RIPA 10 µl/ml phenylmethanesulfonyl fluoride (PMSF), a protease inhibitor, and protein concentrations were determined by a Bicinchoninic Acid (BCA) Protein assay kit. All of these reagents were purchased from the Beyotime Institute of Biotechnology, China. Equal amounts of protein were separated by SDS-PAGE and then transferred to PVDF membranes (Millipore, Billerica, MA, USA), which were blocked with 5% non-fat milk for 2 h before being incubated with the appropriate primary antibodies overnight at 4°C. The membranes were subsequently incubated with the appropriate HRP-conjugated secondary antibodies for 2 h at room temperature. The protein bands were visualized by an Enhanced Chemiluminescence Detection kit (Thermo Scientific, Waltham, MA, USA) and photographed by a Gel Logic 2200 PRO imaging system. The following primary antibodies were used in this experiment: an MTDH rabbit mAb (1:2000, Abcam), an E-cadherin rabbit mAb (1:1000, Cell Signaling Technology, Beverly, MA, USA), a Slug rabbit mAb (1:1000, Cell Signaling Technology), a Snail rabbit pAb (1:1000, Abcam), an N-cadherin mouse mAb (1:1000, Cell Signaling Technology), a ZO-1 mouse mAb (1:2000, Cell Signaling Technology), and a GAPDH mAb-HRP (1:5000, Bioworld Technology, Minneapolis, MN, USA).
+ Open protocol
+ Expand
3

Comprehensive Antibodies for EMT Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
IKBKE rabbit mAb (No.2905 WB 1:1000, IP 1:100), E-cadherin mouse mAb (No.14472 WB 1:1000 IHC 1:100), N-cadherin rabbit mAb (No.13116 WB 1:1000 IHC 1:100), MMP9 rabbit mAb (No.13667 WB 1:1000 IHC 1:100), Slug rabbit mAb (No.9585 WB 1:1000) and YAP1 mouse mAb (No. 12395 WB 1:1000 IHC 1:100 IP 1:100) were obtained from Cell Signaling Technology (USA). β-catenin rabbit polyclonal antibody (ab32572 WB 1:5000 IHC 1:100), Snail rabbit polyclonal antibody (ab180714 WB 1:1000 IHC 1:100), Vimentin rabbit polyclonal antibody (ab45939 WB 1:1000 IHC 1:10000), MMP2 rabbit polyclonal antibody (ab37150 WB 1:1000 IHC 1:100), Twist rabbit polyclonal antibody (ab49254 1:500), TEAD2 rabbit polyclonal antibody (ab83670 WB 1:500) and IKBKE rabbit polyclonal antibody (ab7891 IHC 1:100) were purchased from Abcam (UK). TEAD2 rabbit polyclonal antibody (sc-67115 IP 1:50) were from Santa Cruz (USA). GADPH mouse mAb (TA309157 WB 1:2000) was obtained from ZSGB-BIO (China).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!