The largest database of trusted experimental protocols

Liposofast liposome factory

Manufactured by Merck Group

The LiposoFast Liposome Factory is a laboratory equipment designed for the production of liposomes. Liposomes are spherical vesicles composed of a lipid bilayer, which can be used for various applications in research and development. The LiposoFast Liposome Factory provides a controlled and efficient method for the formation of liposomes.

Automatically generated - may contain errors

2 protocols using liposofast liposome factory

1

Liposome Preparation with DOTAP, DOPE, and Cholesterol

Check if the same lab product or an alternative is used in the 5 most similar protocols
DDC642 liposomes were generated as described by Desmet et al. [21 (link)]. Briefly, DOTAP (Sigma, #D6182-50mg, St.Louis, CA, USA), DOPE (Sigma, #42490-2.5 mL) and cholesterol (Sigma, #C8667-500 mg) were combined in a 6:4:2 ratio, incubated at 37 °C and resuspended in an EtOH/HEPES buffer. After incubation for 24 h at room temperature, the lipid solution was extruded 30 times through a 100-nm pore-sized polycarbonate membrane (Sigma, #Z373419-50EA) using a LiposoFast Liposome Factory (Sigma, #Z373400).
+ Open protocol
+ Expand
2

Preparation of Uniform Liposomes

Check if the same lab product or an alternative is used in the 5 most similar protocols
A liposome kit purchased from Sigma-Aldrich (Catalog Number L4395, St. Louis, MO) was used. The user manual was followed to prepare multilamellar liposomes. Briefly, the lipid mixture was dissolved in CHCl3/CH3OH. The solution was dried under a stream of nitrogen. The vial containing the lipid film was placed under vacuum for 6 hrs to remove the traces of organic solvent. The dry lipid film was hydrated by adding PBS and vigorously shaking with a vortex mixer for >1 min. The MLV suspension were frozen and thawed for 6 cycles. A single freeze-thaw cycle consisted of freezing for 5 min at liquid nitrogen temperature (−196°C) and thawing for 5 min in a water bath at 65°C. Extrusion of the liposome suspension obtained was carried out with a filtration device (LiposoFast Liposome Factory, Sigma-Aldrich Chemicals) through a porous polycarbonate membrane with a pore size of 100 nm to obtain liposomes of uniform size. Size distribution of the liposomes prepared was measured by dynamic light scattering (DLS). Results are shown in Figure S1.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!