Apexii ccd diffractometerabsorption

Manufactured by Bruker

The APEXII CCD diffractometer is a laboratory instrument used for single-crystal X-ray diffraction analysis. It is designed to determine the crystal structure of materials by measuring the diffraction patterns of X-rays interacting with the sample.

Automatically generated - may contain errors

343 protocols using apexii ccd diffractometerabsorption

1

Single Crystal X-ray Diffraction Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols

Bruker APEXII CCD diffractometer

Absorption correction: multi-scan (SADABS; Krause et al., 2015 ▸ ) Tmin = 0.256, Tmax = 0.459

38065 measured reflections

1704 independent reflections

1349 reflections with I > 2σ(I)

Rint = 0.096

+ Open protocol
+ Expand
2

Single Crystal X-ray Diffraction

Check if the same lab product or an alternative is used in the 5 most similar protocols

Bruker Kappa APEXII CCD diffractometer

Absorption correction: multi-scan (SADABS; Bruker, 2004 ▸ ) Tmin = 0.948, Tmax = 0.955

14793 measured reflections

1809 independent reflections

1528 reflections with I > 2σ(I)

Rint = 0.023

+ Open protocol
+ Expand
3

Single Crystal X-ray Diffraction Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols

Bruker APEXII CCD diffractometer

Absorption correction: multi-scan (SADABS; Bruker, 2008 ▸ ) Tmin = 0.92, Tmax = 0.95

46817 measured reflections

5318 independent reflections

4636 reflections with I > 2σ(I)

Rint = 0.035

+ Open protocol
+ Expand
4

Crystal Structure Determination by X-ray Diffraction

Check if the same lab product or an alternative is used in the 5 most similar protocols

Bruker APEXII CCD diffractometer

Absorption correction: multi-scan (SADABS; Bruker, 2005 ▸ ) Tmin = 0.715, Tmax = 0.890

8297 measured reflections

3028 independent reflections

2686 reflections with I > 2σ(I)

Rint = 0.030

+ Open protocol
+ Expand
5

Crystal Structure Determination Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols

Bruker Kappa APEXII CCD diffractometer

Absorption correction: multi-scan (SADABS; Bruker, 2004 ▸ ) Tmin = 0.981, Tmax = 0.985

10595 measured reflections

3454 independent reflections

1668 reflections with I > 2σ(I)

Rint = 0.039

+ Open protocol
+ Expand
6

Single Crystal X-ray Diffraction

Check if the same lab product or an alternative is used in the 5 most similar protocols

Bruker Kappa APEXII CCD diffractometer

Absorption correction: multi-scan (SADABS; Bruker, 2008 ▸ ) Tmin = 0.941, Tmax = 0.960

7690 measured reflections

3638 independent reflections

2447 reflections with I > 2σ(I)

Rint = 0.038

+ Open protocol
+ Expand
7

Single Crystal X-Ray Diffraction Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols

Bruker Kappa APEXII CCD diffractometer

Absorption correction: multi-scan (SADABS; Bruker, 2008 ▸ ) Tmin = 0.875, Tmax = 0.908

6548 measured reflections

4037 independent reflections

3007 reflections with I > 2σ(I)

Rint = 0.019

+ Open protocol
+ Expand
8

Single Crystal X-ray Diffraction Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols

Bruker APEXII CCD diffractometer

Absorption correction: integration (SADABS; Bruker, 2012 ▸ ) Tmin = 0.657, Tmax = 0.745

45528 measured reflections

2621 independent reflections

1626 reflections with I > 2σ(I)

Rint = 0.066

+ Open protocol
+ Expand
9

Single Crystal X-ray Diffraction

Check if the same lab product or an alternative is used in the 5 most similar protocols

Bruker APEXII CCD diffractometer

Absorption correction: multi-scan (SADABS; Bruker, 2012 ▸ ) Tmin = 0.813, Tmax = 0.934

8837 measured reflections

2392 independent reflections

2263 reflections with I > 2σ(I)

Rint = 0.012

+ Open protocol
+ Expand
10

Single Crystal X-Ray Diffraction

Check if the same lab product or an alternative is used in the 5 most similar protocols

Bruker APEXII CCD diffractometer

Absorption correction: multi-scan (SADABS; Bruker, 2009 ▸ ) Tmin = 0.977, Tmax = 0.983

14182 measured reflections

9024 independent reflections

6365 reflections with I > 2σ(I)

Rint = 0.030

+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!