Bruker APEXII CCD diffractometer
Absorption correction: multi-scan (SADABS; Krause et al., 2015 ▸ ) Tmin = 0.256, Tmax = 0.459
38065 measured reflections
1704 independent reflections
1349 reflections with I > 2σ(I)
Rint = 0.096
The APEXII CCD diffractometer is a laboratory instrument used for single-crystal X-ray diffraction analysis. It is designed to determine the crystal structure of materials by measuring the diffraction patterns of X-rays interacting with the sample.
Bruker APEXII CCD diffractometer
Absorption correction: multi-scan (SADABS; Krause et al., 2015 ▸ ) Tmin = 0.256, Tmax = 0.459
38065 measured reflections
1704 independent reflections
1349 reflections with I > 2σ(I)
Rint = 0.096
Bruker Kappa APEXII CCD diffractometer
Absorption correction: multi-scan (SADABS; Bruker, 2004 ▸ ) Tmin = 0.948, Tmax = 0.955
14793 measured reflections
1809 independent reflections
1528 reflections with I > 2σ(I)
Rint = 0.023
Bruker APEXII CCD diffractometer
Absorption correction: multi-scan (SADABS; Bruker, 2008 ▸ ) Tmin = 0.92, Tmax = 0.95
46817 measured reflections
5318 independent reflections
4636 reflections with I > 2σ(I)
Rint = 0.035
Bruker APEXII CCD diffractometer
Absorption correction: multi-scan (SADABS; Bruker, 2005 ▸ ) Tmin = 0.715, Tmax = 0.890
8297 measured reflections
3028 independent reflections
2686 reflections with I > 2σ(I)
Rint = 0.030
Bruker Kappa APEXII CCD diffractometer
Absorption correction: multi-scan (SADABS; Bruker, 2004 ▸ ) Tmin = 0.981, Tmax = 0.985
10595 measured reflections
3454 independent reflections
1668 reflections with I > 2σ(I)
Rint = 0.039
Bruker Kappa APEXII CCD diffractometer
Absorption correction: multi-scan (SADABS; Bruker, 2008 ▸ ) Tmin = 0.941, Tmax = 0.960
7690 measured reflections
3638 independent reflections
2447 reflections with I > 2σ(I)
Rint = 0.038
Bruker Kappa APEXII CCD diffractometer
Absorption correction: multi-scan (SADABS; Bruker, 2008 ▸ ) Tmin = 0.875, Tmax = 0.908
6548 measured reflections
4037 independent reflections
3007 reflections with I > 2σ(I)
Rint = 0.019
Bruker APEXII CCD diffractometer
Absorption correction: integration (SADABS; Bruker, 2012 ▸ ) Tmin = 0.657, Tmax = 0.745
45528 measured reflections
2621 independent reflections
1626 reflections with I > 2σ(I)
Rint = 0.066
Bruker APEXII CCD diffractometer
Absorption correction: multi-scan (SADABS; Bruker, 2012 ▸ ) Tmin = 0.813, Tmax = 0.934
8837 measured reflections
2392 independent reflections
2263 reflections with I > 2σ(I)
Rint = 0.012
Bruker APEXII CCD diffractometer
Absorption correction: multi-scan (SADABS; Bruker, 2009 ▸ ) Tmin = 0.977, Tmax = 0.983
14182 measured reflections
9024 independent reflections
6365 reflections with I > 2σ(I)
Rint = 0.030
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.