The largest database of trusted experimental protocols

Luminex high performance assays

Manufactured by R&D Systems

Luminex high-performance assays are multiplex immunoassay platforms that allow simultaneous detection and quantification of multiple analytes in a single sample. The core function of these assays is to provide a flexible, efficient, and high-throughput solution for measuring a variety of biomolecules, including proteins, cytokines, and other targets.

Automatically generated - may contain errors

2 protocols using luminex high performance assays

1

Biomarkers of Inflammation and Intestinal Damage

Check if the same lab product or an alternative is used in the 5 most similar protocols
Biomarkers were measured on EDTA plasma or serum. Intestinal fatty acid binding protein (I-FABP) was measured using the DuoSet ELISA Kit; sCD14 and IL-6 were measured by ELISA using Quantikine kits; sCD163 and sTNFRII were measured using Luminex high-performance assays (all R&D systems, Minneapolis MN). Serum (1,3)-β-D-glucan was measured using the Fungitell® kit (Associates of Cape Cod, Inc., Falmouth, MA). Other inflammation biomarkers were measured using the Luminex platform (Bio-Plex Pro™ Human Inflammation Panel 1, Bio-Rad Laboratories, Inc., Hercules, CA).
+ Open protocol
+ Expand
2

Secreted Cytokine Profiling of CB Cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
To explore the secreted cytokine profile of the CB populations, Luminex High Performance Assays (R&D Systems) were performed. The supernatant of both freshly sorted UTCs and UTC-derived clones after 24 h of stimulation with phorbol myristate acetate (PMA; 1 ng/ml; 16561-29-8; Sigma-Aldrich) + ionomycin (0.5 µg/ml; 56092-82-1; Sigma-Aldrich) was assessed with the Luminex Performance Human XL Cytokine Magnetic Panel 44-plex Fixed Panel (LKTM014; Bio-Techne). Following this, a custom mixed multiplex was used to determine the IFN-γ, granzyme B, GM-CSF, MIP-1α, MIP-1β, and IL-2 concentrations in the supernatant of both freshly sorted CTCs and UTCs after 24 h of stimulation with PMA + ionomycin. All assays were performed conforming to the manufacturer’s protocol, measured with the Bio-Plex 200 system (Bio-Rad), and analyzed with the Bio-Plex Manager software version 6.2. Levels below or above the detection level were set as the lower or upper detection level, respectively.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!