The largest database of trusted experimental protocols

Model 700

Manufactured by Zeiss
Sourced in Germany

The Model 700 is a precision analytical instrument designed for laboratory use. It features advanced optics and electronics to provide accurate and reliable measurements. The core function of the Model 700 is to perform detailed analysis of samples, but a more detailed description cannot be provided while maintaining an unbiased and factual approach.

Automatically generated - may contain errors

2 protocols using model 700

1

Cytoskeletal Organization on Hybrid Nanofiber Scaffolds

Check if the same lab product or an alternative is used in the 5 most similar protocols
To evaluate cellular cytoskeletal organization on the pristine PLGA, nHA/PLGA, and BMP-g-nHA/PLGA hybrid nanofiber scaffolds, double staining was performed according to the previously reported method [22 (link)]. Briefly, osteoblast cells were seeded onto the nanofiber scaffolds (2 × 104 cells/mL) separately and cultured for 3 days. The cells were then fixed with 4% paraformaldehyde in PBS. After fixation, the samples were washed using a PBS containing 0.05% Tween-20. The samples were permeabilized with 0.1% Triton X-100 in PBS for 15 min at 25°C and then incubated for 30 min in a PBS containing 1% bovine serum albumin (BSA). This was followed by the addition of 5(6)-tetramethyl-rhodamine isothiocyanate-conjugated phalloidin (TRITC Millipore) for approximately 1 h. The nanofiber scaffolds were washed three times (10 min each) using the buffer solution and incubated with 4′,6-diamidino-2-phenylindole (DAPI, Millipore) for 5 min. Fluorescence images were visualized using a confocal laser-scanning microscope (Model 700; Carl Zeiss, Oberkochen, Germany).
+ Open protocol
+ Expand
2

Preoperative Axial Length Measurement in Retinal Detachment

Check if the same lab product or an alternative is used in the 5 most similar protocols
Preoperative AL values of RRD eyes were measured using A-scan ultrasound biometry (UD-6000 Ultrasonic A/B scanner biometer; Tomey Corporation, Nagoya, Japan), as previously described [17 (link)], instead of using IOLMaster. Before SO removal, an optical coherence tomography scan was performed to ensure that the macula was attached in both eyes, and then the AL values of postoperative RRD eyes and fellow eyes were obtained with IOLMaster (Model 700, Carl Zeiss Meditec Ltd, Jena, Germany) using phakic and SO-filled phakic eye programs, respectively. All the AL measurements performed in this study were repeated three times by experienced examiners. The IOL power was calculated based on the constant A of the AcrySof® IQ ReSTOR® SN6AD1 IOL (Alcon Laboratories, Inc., Fort Worth, USA) with the SRK/T formula.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!