1

Microwave Treatment of Tef Flour

Check if the same lab product or an alternative is used in the 5 most similar protocols
Adjustment of the moisture contents (MC) of the tef flour was conducted by adding distilled water to reach 15, 20, and 25% from an initial value of 12% on a wet basis. The flours were continuously mixed while adding the water and then stored for 24 h at 4  ±  2 °C with polyethylene bags for moisture equilibration. A total of 75 g of tef flour of each MC level was weighted and placed in a 1000 mL hermetically sealed cylindrical Teflon® container and treated (900 W, 2450 MHz) in a MW oven (SHARP R-342 Osaka, Japan) for 1, 2, 4, 6, and 8 min in cycles of 10 s of radiation and 50 s of rest. During the treatment, the Teflon® containers were continuously rotated (60–70 rpm) to distribute radiation evenly. The temperature in the containers was controlled using Testoterm® temperature strips (TESTO, Madrid, Spain). The treated flours were dried at 35 °C in an incubation chamber (Memmert ICP260, Schwabach, Germany) until their MC reached 12%, and then sieved to <500 µm.
+ Open protocol
+ Expand
2

X-ray Diffraction Analysis of Materials

Check if the same lab product or an alternative is used in the 5 most similar protocols
XRD assay was performed using a Bruker-D8-Discover-A25 diffractometer (Bruker AXS, Rheinfelden, Germany) equipped with a CuKα radiation (λ = 0.154 nm) operating at 40 kV and 30 mA. Prior to measurement, all samples were equilibrated to 15% humidity using an incubation chamber (Memmert ICP260, Schwabach, Germany) at saturated humidity and 15 °C. Diffractograms and crystallinity were obtained as described by Villanueva et al. [11 (link)], in the range of 5–40° (2θ) at a rate of 1.2°/min, a scan step size of 0.02°, a divergence slit width of 1°, and a scatter slit width of 2.92°.
+ Open protocol
+ Expand
3

Moisture Content Determination of Rice Flour

Check if the same lab product or an alternative is used in the 5 most similar protocols
Rice flour MC was measured with the AACC 44-19.01 Official Method (AACC, 1999) . Six batches at different MCs of 3 %, 8 %, 13 %, 15 %, 20 %, and 30 % ± 0.5 % were prepared. The MC of 3% was obtained by rice flour lyophilization in FreeZone 1, Labconco lyophilizer (Kansas City, USA). The MC of 8 % was obtained by drying the native flour in an incubation chamber (Memmert ICP260, Schwabach, Germany) at 40 ºC until the desired MC was achieved. The natural rice flour MC was 13 %. The water needed to reach the levels of 15 %, 20 %, and 30 % was added as was described by Villanueva, Harasym, et al. (2018)
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!