Unity 500

Manufactured by Bruker

The Unity 500 is a nuclear magnetic resonance (NMR) spectrometer designed for high-resolution structural analysis. It provides precise measurements of molecular structure and dynamics. The core function of the Unity 500 is to facilitate advanced NMR spectroscopy for research and analytical purposes.

Automatically generated - may contain errors

4 protocols using unity 500

1

Purification and Characterization of Bioactive Compound

Check if the same lab product or an alternative is used in the 5 most similar protocols
The active fraction D was purified by HPLC (Waters: controller 600, pump 600, dual λ absorption detector 2487, Linear Recorder); column C18 (250 × 7.8 mm2 UP ODS); mobile phase: linear gradient of methanol–H2O from 0 to 100% for 52 min; flow rate: 1 mL/min, λ detection at 220 nm and at 420 nm. The column temperature was 30 °C. The injection volume was 200 µL. Under these conditions, the retention time was recorded at 17.6 min. This fraction was shown to contain two main peaks, D1 and D2, but only D2 showed both phosphate-solubilizing and anti-microbial activities.
After purification of the active compound present in D2 by HPLC, the latter was subjected to spectroscopic studies. 1H NMR spectroscopy: Varian Unity 500 (500 MHz), Bruker AMX 500 (500 MHz), Varian Inova 500 (500.33 MHz). 13C NMR spectroscopy: Varian Unity 500 (125.8 MHz), Varian Inova 500 (125.8 MHz). Chemical shifts were measured relative to tetramethylsilane as an internal standard. The homonuclear and heteronuclear 1D and 2D NMR spectra were recorded on a Varian Inova 500 instrument. Mass spectrometry was performed with an LCC ion-trap mass spectrometer (INSERM, Purpan, Toulouse). Samples were analyzed by electrospray ionization in both negative and positive ion mode, and the full-scan mass range (m/z) was 100–2000.
+ Open protocol
+ Expand
2

Synthesis of Dendrimer G3Si(SC2H4NHFITC)(SC2H4CO2Na)31

Check if the same lab product or an alternative is used in the 5 most similar protocols
Dendrimer G3Si(SC2H4NHFITC)(SC2H4CO2Na)31 was synthesized following the protocol described in the bibliography with the appropriate modifications described [50 (link)]. The procedure is described below. Solvents and the chemicals were purchased from commercial sources and used without prior treatment. Thiol-ene reactions were carried out using a UV lamp that radiates vertically (high efficiency with VL-115.L Viber Lourmat filter, 365 nm emission, 30 W, 1100 µW/cm2). NMR experiments were performed on Varian spectrometers, Mercury-300 or Unity-500 spectrometers or Bruker AV400, at ambient temperature. The chemical shifts (ppm) were measured relative to the residual signal of 1H of the deuterated solvents. Infrared spectra were measured in the IR-FT Perkin-Elmer Spectrum 2000, and ultraviolet spectra were taken from the UV-Vis spectrophotometer Perkin-Elmer Lambda 35.
+ Open protocol
+ Expand
3

Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All starting materials, reagents and solvents were purchased from Sigma-Aldrich, Inc., Tokyo Chemical Industry Co., Ltd and Nacalai Tesque, Inc., and analytical reagents were used without further purification. 1H-nuclear magnetic resonance (NMR) (500 MHz), 13C-NMR (125 MHz) and 31P-NMR (202 MHz) spectra were recorded by Varian UNITY-500 and Bruker Ascend-500 spectrometers. High-resolution mass spectra were recorded by Bruker microTOF II. Spectra obtained by matrix-assisted laser desorption ionization-time of flight-mass spectrometry (MALDI-TOF-MS) were recorded by Bruker Autoflex II. DNA concentrations were measured by NANODROP ONE. The gel was visualized using the FUJIFILM Luminoimage analyzer LAS-4000.
+ Open protocol
+ Expand
4

Spectroscopic Analysis of 2-Chloroquinoline-3-carbaldehyde

Check if the same lab product or an alternative is used in the 5 most similar protocols
Melting points were measured on a Boetius apparatus and are uncorrected. IR spectra were taken in KBr pellets on a Nicolet 380 FTIR 1600 spectrometer. Elemental analyses were performed on a Vario El Cube CHNS analyzer and the results are within ±0.4%. NMR spectra were recorded on a Varian Gemini 200, a Varian Unity 500, or a Bruker Avance III HD apparatus. 1H and 13C chemical shifts were measured relative to the residual solvent signal at 7.26 ppm and 77.0 (CDCl3) or 2.50 ppm and 39.5 ppm (DMSO-d6). Coupling constants are shown in hertz (Hz). The mass spectra were recorded on a Shimadzu LCMS-2010 EV spectrometer equipped with an electrospray source. ESI-MS spectra were registered in a positive- or negative-ion mode. Preparative thin layer chromatography was performed on silica gel 60 PF254 containing gypsum (Merck KGaA, Darmstadt, FRG) with the aid of Chromatotron® using the reported solvent systems. 2-Chloroquinoline-3-carbaldehyde (1) was obtained according to the published method [57 (link)]. UV-Vis spectra were recorded with an Analytik Jena Spekol 1200 (Analytik Jena AG, Jena, Germany) in a 1.0 cm cuvette maintained at 37 °C by a thermostatically controlled cuvette holder.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!