The largest database of trusted experimental protocols

Magnetom avanto 1.5 t system

Manufactured by Siemens
Sourced in Germany

The Magnetom Avanto 1.5 T system is a magnetic resonance imaging (MRI) scanner manufactured by Siemens. It is a 1.5 Tesla superconducting magnet system designed for diagnostic imaging applications.

Automatically generated - may contain errors

Lab products found in correlation

3 protocols using magnetom avanto 1.5 t system

1

Diffusion Weighted Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
DWI were acquired using Magnetom Avanto 1.5 T system (Siemens Medical Solutions, Erlangen, Germany). The sequence parameters are reported in Table 1. DWI images were acquired using ten b values 0, 10, 20, 50, 70, 100, 150, 200, 500, and 1000 (s/mm2).
+ Open protocol
+ Expand
2

Diffusion-Weighted MRI Protocol Comparison

Check if the same lab product or an alternative is used in the 5 most similar protocols
DW-MRI images were acquired using Achieva 1.5 T system (Philips Medical system, Eindhoven, Netherlands)—5 patients—or a Magnetom Avanto 1.5 T system (Siemens Medical Solutions, Erlangen, Germany)—13 patients—both with a body-matrix coil and spine array coil for signal reception. The data were acquired axially by means of echo planar imaging. The sequences’ parameters (for both equipment) are reported in Table 1. Diffusion-weighted images (DWI) were acquired using four b values (50, 400, 800, and 1000 s/mm2).

MRI sequence parameters by MRI scanners

Sequence parameterSTS databaseOPC database
Siemens Avanto (n = 13)Philips Achieva (n = 5)Siemens Avanto (n = 18)
Sequence nameep2ddwi_sshep2d
Matrix (pixels)192 × 192255 × 255132 × 132
Resolution (voxel/mm)1.98 × 1981.37 × 1.371.89 × 1.89
Field of view (mm)380 × 380350 × 350250 × 250
Repetition time (msec)540074103300
Echo time (msec)786364
Slice thickness (mm)4 (no gap)5 (no gap)3 (gap 0.9)
Number of excitations433
+ Open protocol
+ Expand
3

Diffusion-Weighted MRI Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
DWI MRI images were acquired using Achieva 1.5T system (Philips Medical system Achieva, Nederlands) (6 patients) or a Magnetom Avanto 1.5T system (Siemens Medical Solutions, Erlangen, Germany) (13 patients), both with a body-matrix coil and spine array coil for signal reception. The data were acquired axially by means of echo planar imaging, the sequences' parameters (for both equipment) are reported in Table 2. DWI images were acquired using four b-values (namely, 50, 400, 800, and 1000 s/mm 2 )
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists