Quanta lite ccp3

Manufactured by Inova Diagnostics
Sourced in United States

The QUANTA Lite CCP3 is an enzyme-linked immunosorbent assay (ELISA) test kit used to detect and measure the levels of anti-cyclic citrullinated peptide (anti-CCP) antibodies in human serum or plasma samples. The anti-CCP antibodies are associated with rheumatoid arthritis, an autoimmune disease.

Automatically generated - may contain errors

2 protocols using quanta lite ccp3

1

Evaluating CCP3 Antibodies in Anti-CCP2 Individuals

Check if the same lab product or an alternative is used in the 5 most similar protocols
For the 469 anti-CCP2− individuals, stored serum samples obtained from 2008 to 2018 were tested for CCP3 IgG (QUANTA Lite CCP3; Inova Diagnostics). CCP2 and CCP3 testing was performed on the same stored serum samples. The threshold for a positive CCP3 antibody test was >20 units, according to the manufacturer’s cut-off. In addition, alternative cut-off values were evaluated derived from optimised F-1 score analysis.
+ Open protocol
+ Expand
2

Anti-CCP Antibody Detection by ELISA

Check if the same lab product or an alternative is used in the 5 most similar protocols
Anti-CCP was detected by Quanta Lite CCP3 enzyme-linked immunosorbent assay (ELISA) kits (Inova Diagnostics, San Diego, CA, USA) in accordance to the manufacturer’s recommendations. ELISA plates (BD Biosciences, San Jose, CA, USA) were coated for 2 h at 37 °C with 1 μg/mL GRP78 or CarGRP78 in coating buffer containing 35 mM NaHCO3 and 15 mM Na2CO3, pH 9.6. The plates were washed with phosphate-buffered saline (PBS) for four times and blocked with PBS containing 2% skim milk overnight. Then, Quanta Lite reagents (Inova Diagnostics, San Diego, CA, USA) were used for performing ELISA according to the supplier’s protocol. The plates were read at 405 nm on an Anthos Zenyth 3100 multimode fluorometer (Anthos Labtec Instruments GmbH, Salzburg, Austria). All samples were analyzed at the same time. The absorbance values of control wells were low in all cases. The cutoff values for the anti-GRP78 and anti-CarGRP78 antibody ELISA was defined as the mean plus two standard deviations of the controls.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!