The largest database of trusted experimental protocols

2 protocols using sodium hydroxide solution 1 n

1

Formulation and Characterization of Losartan Potassium Tablets

Check if the same lab product or an alternative is used in the 5 most similar protocols
Losartan potassium (Form I, Dr. Reddy’s Laboratories, Jinnaram Mandal, Telangana, India), silicified microcrystalline cellulose (PROSOLV® SMCC 50, JRS Pharma, Rosenberg, Germany), copovidone (Kollidon® VA 64 (Fine), BASF Pharma, Ludwigshafen, Germany), crospovidone (Kollidon® CL, BASF, Ludwigshafen, Germany), dicalciumphosphate anhydrous (DI-CAFOS® A 150, Chemische Fabrik Budenheim, Budenheim, Germany), lactose (Tablettose® 80, Flowlac® 100, MEGGLE, Wasserburg am Inn, Germany), isomalt (galenIQTM 721, BENEO-Palatinit, Mannheim, Germany), microcrystalline cellulose (VIVAPUR® 102, JRS Pharma, Rosenberg, Germany), Ludipress® (BASF Pharma, Ludwigshafen, Germany), magnesium stearate (Parteck® LUB MST, Merck, Darmstadt, Germany), sodium stearyl fumarate (PRUV®, JRS Pharma, Rosenberg, Germany), talc (Talkum® Pharma G, C.H. Erbslöh, Krefeld, Germany), HPMC (PHARMACOAT® 603, Shin-Etsu Chemical, Tokyo, Japan), macrogol (PEG 6000, BASF Pharma, Ludwigshafen, Germany), methanol (HPLC grade, VWR Chemicals, Radnor, PA, USA), acetonitrile (HPLC grade, Honeywell, Charlotte, NC, USA), phosphoric acid (Merck, Darmstadt, Germany), monobasic potassium phosphate (Fisher Scientific, Waltham, MA, USA), disodium hydrogen phosphate anhydrous (AppliChem, Darmstadt, Germany), and sodium hydroxide solution 1 N (Merck, Darmstadt, Germany) were used.
+ Open protocol
+ Expand
2

Analytical Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Sodium chloride and hexane (≥95%) were obtained from Fisher Scientific (Pittsburgh, PA, USA). Sodium sulphate (anhydrous) was obtained from ECP-Analytical (Auckland, New Zealand). 4-Decanone* (≥97.0%) was obtained from Tokyo Chemical Company (Tokyo, Japan). 4-Methyl-2-pentanone* (≥98%) was obtained from BDH Chemicals Ltd. (Poole, UK). Dichloromethane (≥99.9%), methanol (≥99.8%), sodium hydroxide solution (1N), 3-octanone (≥98%), δ-octalactone (98%), γ-decalactone (≥98%), δ-decalactone (≥98%), γ-dodecalactone (≥97%), δ-dodecalactone (≥97%), δ-tetradecalactone (98%) were obtained from Merck (Darmstadt, Germany). A C7-C30 Saturated Alkane Standard was obtained from Supelco (Bellefonte, PA, USA). Liquid nitrogen, liquid carbon dioxide, hydrogen carrier gas (instrument grade, >99.98%), and nitrogen (instrument grade, >99.99%) were obtained from BOC Ltd. (Auckland, New Zealand).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!