The largest database of trusted experimental protocols

Silver silver chloride reference electrode ag agcl

Manufactured by CH Instruments
Sourced in United States

The Silver/silver chloride reference electrode (Ag/AgCl) is a type of reference electrode used in electrochemical measurements. It consists of a silver wire coated with silver chloride, immersed in a potassium chloride (KCl) solution. The Ag/AgCl electrode provides a stable and reproducible reference potential, which is an essential component in various electrochemical techniques and applications.

Automatically generated - may contain errors

2 protocols using silver silver chloride reference electrode ag agcl

1

Carbon Nanotube Electrochemical Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
All solutions were prepared with distilled/deionized water (18 MΩ resistivity, Darmstadt, Germany). Carbon nanotubes were obtained from Material Science & Nanotechnology Laboratory (IVIC, Caracas, Venezuela). Nitric acid (HNO3, 69.2 wt.%) and hydrogen peroxide (H2O2, 30%V/V) were purchased from Sigma-Aldrich Sigma, (Darmstadt, Germany). Potassium phosphate monobasic (KH2PO4) and sodium hydroxide (NaOH, 99.9% p/p) were purchased from Fisher Scientific (Waltham, MA, USA). Phosphate-buffered saline (PBS, 20 mmol·L−1 KH2PO4 + 20 mmol·L−1 K2HPO4 + 0.1 mol·L−1 KCl, pH 6.8) was used as a supporting electrolyte. Potassium ferricyanide (K3[Fe(CN)6]), iron trichloride hexahydrated (FeCl3·6H2O), and potassium chloride (KCl) were from BDH Chemicals (Philadelphia, PA, USA), hydrochloric acid (HCl, 37%) was from Fisher Scientific (Waltham, MA, USA), glassy carbon (GC, diameter ( Φ=3 mm ), geometric area = 0.0706 cm2), silver/silver chloride reference electrode (Ag/AgCl), and graphite rod counter-electrode were from CH-Instruments (Austin, TX, USA), sulfuric acid (H2SO4, 98%) was from Fisher Scientific (Waltham, MA, USA), and 1 µm, 0.3 µm, and 0.05 µm alumina powder were from CH-Instruments (Austin, TX, USA), dimethylformamide (DMF) was from BDH Chemicals (Philadelphia, PA, USA), poly (diallyldimethylammonium chloride) (PDDA, 4% w/w in water) were from Sigma.
+ Open protocol
+ Expand
2

Electrochemical Analysis of Carbon Nanotubes

Check if the same lab product or an alternative is used in the 5 most similar protocols
All solutions were prepared with distilled/deionized water (18 MΩ resistivity, Darmstadt, Germany). Carbon nanotubes were obtained from NANOCYL®NC7000(Austin, TX, USA). Nitric acid (HNO3, 69.2 wt%) and hydrogen peroxide ( H2O2 30% v/v) were purchased from Sigma-Aldrich (Darmstadt, Germany). Potassium phosphate monobasic ( KH2PO4 ) and sodium hydroxide (NaOH, 99.9% p/p) were purchased from Fisher Scientific (Waltham, MA, USA). Phosphate-buffered saline (PBS: KH2PO4 + K2HPO4 + KCl, at different pH values) was used as a supporting electrolyte. Potassium ferricyanide ( K3[Fe(CN)6] ), iron trichloride hexahydrated ( FeCI36H2O ), and potassium chloride (KCl) were obtained from BDH Chemicals (Philadelphia, PA, USA); hydrochloric acid (HCl, 37%) was from Fisher Scientific (Waltham, MA, USA); glassy carbon (GC, Φ=3mm , geometric area = 0.0706 cm2), silver/silver chloride reference electrode (Ag/AgCl), and graphite rod counter electrode were from CH Instruments (Austin, TX, USA); sulfuric acid ( H2SO4 , 98%) was from Fisher Scientific (Waltham, MA, USA); 1 μm, 0.3 µm, and 0.05 µm alumina powder were from CH Instruments (Austin, TX, USA); dimethylformamide (DMF) was from BDH Chemicals (Philadelphia, PA, USA); and poly (diallyldimethylammonium chloride) (PDDA, 4% w/w in water) was from Sigma.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.