The largest database of trusted experimental protocols

Loopamp real time turbidimeter la 200

Manufactured by Eiken Chemical

The Loopamp real-time turbidimeter LA-200 is a laboratory instrument designed for real-time monitoring of turbidity in reaction mixtures. It measures the optical density of the sample to provide information about the turbidity levels during the reaction process.

Automatically generated - may contain errors

2 protocols using loopamp real time turbidimeter la 200

1

LAMP Amplification of Plasmid and Genomic DNA

Check if the same lab product or an alternative is used in the 5 most similar protocols
The reactions were performed using a Loopamp DNA Amplification Reagent Kit (Eiken Chemical). Detection of the LAMP amplicons was performed by real-time measurements of turbidity using a Loopamp real-time turbidimeter LA-200 (Eiken Chemical) and visual observations of the colour changes with the naked eye under natural light. The final reaction volume was 25 μL, comprising 40 pmol of the FIP primer and 40 pmol of the BIP primer, 20 pmol of each loop primer, 5 pmol of F3 and B3 primers, 1 μL of the Bst DNA polymerase, reaction buffer (20 mM Tris–HCl, 10 mM KCl, 8 mM MgSO4, 10 mM (NH4)2SO4, 0.1% Tween 20, 0.8 M betaine, and 1.4 mM each dNTP), and 1 μL of plasmid DNA or 8 μL of genomic DNA samples. Reactions were carried out at 62, 63, 64, and 65 °C in duplicate to find the optimum temperature for the LAMP amplification.
+ Open protocol
+ Expand
2

RT-LAMP for SARS-CoV-2 Detection

Check if the same lab product or an alternative is used in the 5 most similar protocols
According to the manufacturer’s instructions, RT-LAMP was performed using the Loopamp SARS-CoV-2 Detection kit (Eiken Chemical Co., Ltd., Tokyo, Japan). The reaction volume of 25 μL contained 10 μL of purified RNA and 15 μL of reaction mix containing 172.3 ng/μL of SARS-CoV-2 specific primer sets. The mixture was incubated for 35 min at 62.5 °C, and the process was monitored using a Loopamp Real-time Turbidimeter (LA-200; Eiken Chemical). For visual evaluation of fluorescence, the reaction tube was illuminated with ultraviolet light using an ultraviolet illumination system (WSE-5300; ATTO, Tokyo, Japan) and observed by the naked eye.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!