6 protocols using octadecanethiol

1

Substrate Preparation and Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
In all experiments, deionized water (18.2 MΩ·cm) was obtained from a Millipore filtration system (Milli-Q IQ7003, Darmstadt, Germany). The silicon wafer (p-doped) or borosilicate glass substrates were cleaned by oxygen plasma before use. The self-assembled molecules of Octadecanethiol (ODT, 98%), PS spheres aqueous suspension (10 wt%), Rhodamine 6G (R6G, 99%), and glucose (99.5%) were all purchased from Sigma Aldrich (Trondheim, Norway). In addition, acetone and absolute ethanol (99.5%, VWR chemicals, Trondheim, Norway) were used as received without further purification.
+ Open protocol
+ Expand
2

Cell Adhesion Protein Sourcing

Check if the same lab product or an alternative is used in the 5 most similar protocols
General laboratory chemicals and reagents were purchased from VWR. Cell culture reagents, and antibodies were purchased from Life Technologies. Octadecanethiol, fibronectin, collagen IV, collagen II, and laminin were purchased from Sigma-Aldrich. Formaldehyde was purchased from Ted Pella, Inc.
+ Open protocol
+ Expand
3

Fabrication of Self-Assembled Monolayers

Check if the same lab product or an alternative is used in the 5 most similar protocols
Deionized water (18.2 MΩ·cm)
was obtained from a Millipore filtration system. Glass substrates
were cleaned by oxygen plasma before use. Octadecanethiol (ODT, 98%),
16-mercaptohexadecanoic acid (MHDA), Cu(ClO4)2, polystyrene spheres (500 nm, 10 wt % in water, Product no. 59769,
Sigma-Aldrich) and methylene blue (MB, 99%) were purchased from Aldrich.
Acetone (99.5% purity) and absolute ethanol (99.5% purity) were used
as received from VWR without further purification.
+ Open protocol
+ Expand
4

Surface Modification of Glass Substrates

Check if the same lab product or an alternative is used in the 5 most similar protocols
Borosilicate glass substrates were cleaned by oxygen plasma before use. Octadecanethiol (ODT, 98%), 10 wt% aqueous suspensions of 200-nm, 500-nm and 1000-nm PS nanospheres, and Rhodamine 6G (R6G, 99%) were purchased from Sigma Aldrich (Darmstadt, Germany). A 1-wt.% aqueous suspension of 50-nm PS nanospheres was purchased from Phosphorex (Hopkinton, MA, United States). Acetone and absolute ethanol (99.5%, VWR chemicals, Oslo, Norway) were used as received without further purification.
+ Open protocol
+ Expand
5

Synthesis of Silver-Alkylthiolate Coordination Polymer

Check if the same lab product or an alternative is used in the 5 most similar protocols
Alkylthiolate–silver coordination polymer was prepared referring to the previous literatures [19 (link)]. Silver nitrate (AgNO3, 4.9 × 10−3 mol; Sigma-Aldrich, Inc., St. Louis, MO, USA) was dissolved in a mixed solvent (50 mL of tetrahydrofuran (THF; Daejung Chemicals & Metals CO., LTD., Siheung, South Korea) and 25 mL of ethanol (EtOH; Daejung Chemicals & Metals CO., LTD., Tokyo South Korea)), and octadecanethiol (9.1 × 10−3 mol; Sigma-Aldrich, Inc., St. Louis, MO, USA) was dissolved in 50 mL of THF solvent. Both solutions were mixed and vigorously stirred under ambient condition. After 24 h, the obtained precipitate was separated by centrifugation and unreacted octadecanethiol moiety was washed out utilizing THF and EtOH. Thus obtained product, AgS(CH2)17CH3 coordination polymer (AgSC18) was dried in vacuum oven.
+ Open protocol
+ Expand
6

Fabrication of Electrochemical Sensors

Check if the same lab product or an alternative is used in the 5 most similar protocols
Bovine serum albumin (BSA), 1H,1H,2H,2H-perfluorodecanethiol, ferric nitrate, acetaminophen and octadecanethiol were purchased from Sigma Aldrich (St. Louis, MO). Thiourea and glucose was obtained from Alfa Aesar (Ward Hill, MA). Glutaraldehyde was acquired from Electron Microscopy Sciences (Hatfield, PA). Glucose oxidase and FeCl3 were obtained from Amresco (Solon, OH). NaCl, KCl, NaH2PO4, Na2HPO4 were acquired from Avantor Performance Materials (Center Valley, PA). The e-jet printing needle (glass micropipette) was purchased from World Precision Instruments (Sarasota, FL). Perfluorosulfonic acid (PFSA) in 1-propanol and water was purchased from Ion Power (New Castle, DE). The photoresist SU-8 was acquired from Microchem (Westborough, MA). Sylgard 184 PDMS was obtained from Dow Corning (Midland, MI). The Pt and Ag plating solution were purchased from Technic (Cranston, RI). Au (150 nm thick) on 12.7 μm polyimide (PI) film was acquired from Sheldahl (Northfield, MN). Milli-Q water (18.2 MΩ cm) was used in all sample preparation.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.