Waters q tof premier

Manufactured by Waters Corporation
Sourced in Japan, Germany

The Waters-Q-TOF-Premier is a high-performance liquid chromatography-mass spectrometry (LC-MS) system designed for accurate mass measurement and structural elucidation. It combines a quadrupole time-of-flight (Q-TOF) mass analyzer with a high-resolution chromatographic separation capability. The system is capable of providing precise mass data for the identification and quantification of a wide range of analytes in complex matrices.

Automatically generated - may contain errors

4 protocols using waters q tof premier

1

NMR Spectroscopy Analysis Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
NMR spectra were obtained on Bruker AV-400
MHz and AV-600 MHz spectrometers. The 1H NMR chemical shifts
were measured relative to CDCl3 or DMSO-d6 as the internal reference (CDCl3: δ
= 7.26 ppm; DMSO-d6: δ = 2.50 ppm).
The 13C NMR chemical shifts were given using CDCl3 as the internal standard (CDCl3: δ = 77.16 ppm;
DMSO-d6: δ = 39.52 ppm). High-resolution
mass spectra (HRMS) were obtained with a Waters-Q-TOF-Premier (ESI).
Unless otherwise noted, all reagents were obtained from commercial
suppliers and used without further purification.
Unless otherwise
noted, all reagents were obtained from commercial suppliers and used
without further purification. PivOD (>95% deuterium incorporation
by 1H NMR analysis)20 (link) and 2-deuterated
benzo[b]thiophene (>95% deuterium incorporation
by 1H NMR analysis)21 (link) were prepared
according to the literature procedures. Ultradry solvents including N,N-dimethylformamide (DMF), dimethyl sulfoxide (DMSO),
isopropanol (IPA), 1,2-dichloroethane (DCE), and 1,4-dioxane were
purchased from J&K Scientific. Tetrahydrofuran (THF) and methyl tert-butyl ether (MTBE) were dried by refluxing over Na
and freshly distilled prior to use.
+ Open protocol
+ Expand
2

Spectroscopic Characterization of Natural Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
The 1D- and 2D-NMR spectra were obtained using a Bruker Avance 400 instrument (Bruker Co. Ltd., Bremen, Germany) with solvent signal as an internal reference. The EI-MS and HR-ESI-MS spectra were measured using JEOL JMS-K9 (JEOL Co. Ltd., Tokyo, Japan) and Waters Q-Tof Premier (Waters Corporation, Manchester, UK), respectively. The HPLC analyses were performed on a Shimadzu VP (Shimadzu Co. Ltd., Kyoto, Japan) equipped with a RF-10AXL fluorescence detector using a l-column ODS (5 µm, ø 4.6 × 250 mm; CERI, Tokyo, Japan). Flash column chromatography was performed on Isolera one (Biotage, Uppsala, Sweden).
+ Open protocol
+ Expand
3

Characterization of Thiophene 1,1-Dioxide Derivatives

Check if the same lab product or an alternative is used in the 5 most similar protocols
NMR spectra
were obtained on Bruker AV-400
and AV-600 MHz spectrometers. The 1H NMR chemical shifts
were measured relative to CDCl3 or DMSO-d6 as the internal reference (CDCl3: δ
= 7.26 ppm; DMSO-d6: δ = 2.50 ppm).
The 13C NMR chemical shifts were given using CDCl3 as the internal standard (CDCl3: δ = 77.16 ppm;
DMSO-d6: δ = 39.52 ppm). Melting
points were determined with XRC-1 and uncorrected. High-resolution
mass spectra (HRMS) were obtained with a Waters-Q-TOF-Premier (ESI).
Unless otherwise noted, all reagents were obtained from commercial
suppliers and used without further purification. Thiophene 1,1-dioxide
derivatives were prepared according to the literature procedures.15 (link) Arylboronic acids were purchased from Energy
Chemical. DCE, DMF, and DMSO were dried by refluxing over CaH2. Toluene and 1,4-dioxane were dried by refluxing over Na
and freshly distilled prior to use.
+ Open protocol
+ Expand
4

Mass Spectrometry Techniques for Chemical Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
EI mass spectrometry: a Varian
320 MS Triple Quad GC/MS/MS instrument (Varian, Darmstadt, Germany)
with a Varian 450-GC usually operating in direct mode (DEP method)
using electron impact ionization (70 eV). In the case of chlorinated
and brominated compounds, all peak values of molecular ions as well
as fragments refer to the isotopes 35Cl and 79Br, respectively. ESI mass spectrometry: an LC-MSD Series 1100 (Agilent/Hewlett
Packard, Santa Clara, CA, US). High-resolution ESI mass spectrometry:
a Waters Acquity UPLC coupled to a Waters Q-TOF Premier (Waters, Eschborn,
Germany) or an LC-System 1260 Infinity II (Agilent Technologies, Santa
Clara, CA, US), coupled to a Bruker Impact II (Bruker, Bremen, Germany).
High-resolution EI mass spectrometry: a Waters Micromass GCT (Waters,
Eschborn, Germany) operating in direct mode. All HRMS results were
satisfactory relative to the calculated accurate mass of the molecular
ion (±2.3 ppm, R ≈ 10 000).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.