Manufactured by Omron

The Omron 705IT (HEM-759-E) is a blood pressure monitor designed for professional use in medical settings. It is capable of measuring blood pressure and pulse rate.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using 705it hem 759 e

1

Validating Automated Blood Pressure Monitoring

Check if the same lab product or an alternative is used in the 5 most similar protocols
Systolic and diastolic blood pressure (SBP; DBP) were measured using an Omron 705IT (HEM-759-E; Omron Healthcare Europe BV, Hoofddorp, the Netherlands). This is a fully automated upper-arm oscillometric blood pressure monitoring device that is clinically validated by the Association for the Advancement of Medical Instruments, the European Society of Hypertension, and the British Hypertension Society (e.g., Refs. [33 (link),34 (link)]). SBP and DBP were measured twice in succession at each time point and averaged into a single value for statistical analyses. Cortisol was assessed by taking saliva samples with synthetic Salivettes (Sarstedt®, Etten-Leur, the Netherlands). Samples were stored at −20 °C within 1 h of collection. Cortisol levels were determined by a commercially available luminescence immuno-assay (IBL, Hamburg, Germany).
+ Open protocol
+ Expand
2

Stress Assessment in Psychological Task

Check if the same lab product or an alternative is used in the 5 most similar protocols
A visual analogue scale (VAS) was used to assess subjective stress related to the MAST, asking how stressful participants had felt during the task, how painful it was and how unpleasant it felt (anchored from ‘not at all’ to ‘very’). Negative affect was assessed using the negative items from the PANAS (Fig. 1).
To assess general arousal and SAM axis activity, the systolic and diastolic blood pressure (SP and DP) and pulse were measured using the Omron 705IT (HEM‐759‐E; Omron Healthcare Europe BV, Hoofddorp, the Netherlands). Mean arterial pressure (MAP) was calculated to obtain one total value representing averaged blood pressure [MAP = DP + 0.412 (SP − DP)] (Meaney et al., 2000). Cortisol (HPA axis) measures of stress were obtained at four time points during the session using a synthetic Salivette (Sarstedt, Etten‐Leur, the Netherlands). Two baseline samples were taken at t0 and t45, one 15 min after the end of the MAST at t70, and one at the end of the session at t100. Timing was based on the information that the cortisol response peaks 10–20 min after the offset of the MAST (Smeets et al., 2012). After collection, saliva samples were immediately stored at −20 °C. Cortisol levels were determined by a commercially available luminescence immuno assay kit (IBL, Hamburg, Germany).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!