The largest database of trusted experimental protocols

On target non targeting pool

Manufactured by Thermo Fisher Scientific

The ON-TARGET Non-Targeting Pool is a collection of small interfering RNAs (siRNAs) designed to have minimal off-target effects. The pool is intended for use as a control in gene knockdown experiments to help distinguish on-target from off-target effects.

Automatically generated - may contain errors

2 protocols using on target non targeting pool

1

Silencing Caveolin-1 in VSMCs

Check if the same lab product or an alternative is used in the 5 most similar protocols
To silence caveolin-1 expression, 50 nm siRNA against caveolin-1 (s2448, Life Technology) and non-targeting siRNA (ON-TARGET Non-Targeting Pool, Thermo Scientific) was transfected into VSMCs using (Thermo Scientific). Transfection was performed 48 h prior to mechanical stretch exposure.
+ Open protocol
+ Expand
2

RNA Silencing of PARP14 and PARP9

Check if the same lab product or an alternative is used in the 5 most similar protocols
RNA silencing was performed as described previously58 (link). Briefly, 20 nmol l−1 siRNA against PARP14 (L-023583 for human cells and L-160447 for mouse cells) and PARP9 (L-014734 for human cells and L-05024901 for mouse cells; all ONTARGETplus SMART-pool, Thermo Scientific) or non-targeting siRNA (scramble control siRNA, ON-TARGET Non-Targeting Pool, Thermo Scientific) was transferred into macrophages using SilenceMag (BOCA Scientific, Boca Raton, FL), according to the manufacturer's instruction. Target sequences of siRNA pool were follows:
Human PARP14: 5′-UAAUCAAAGGUCUCUUAUG, UAAUGCUUAAGGUCCUCAU, UCAUUAUACUGCCAUUCUA-3′ and 5′-GAACUCUUGACAUCAUUUC-3′,
Human PARP9: 5′-AAUUACAUCUGCCGUCUGC-3′, 5′-UUUGUGGCAAGAAAUUCCG-3′, 5′-UUAAUCAACAGGGCUGCCA-3′ and 5′-UACAGCCAAACUUAUUCUG-3′
Mouse PARP14: 5′-CUUGAAAGCUUUACGUAUA-3′, 5′-CAGCAAUAGGAACGGGAAA-3′, 5′-CCAAAGAACUUGAUCAACA-3′ and 5′-CGUAGUAGCAAAAGCGAUA-3′,
Mouse PARP9: 5′-ACACAAUGUCUUCGAAAUU-3′, 5′-CCAGACAGCUAUCGAAUUA-3′, 5′-CCAAAUAUGAUCUACGCAU-3′ and 5′-CGUACACAUUUCAACGAUA-3′.
Control scramble: 5′-UGGUUUACAUGUCGACUAA-3′, 5′-UGGUUUACAUGUUGUGUGA-3′, 5′-UGGUUUACAUGUUUUCUGA-3′ and 5′-UGGUUUACAUGUUUUCCUA-3′.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!