HRMS analyses were carried out with a 7890B gas chromatograph connected to a 7200 accurate-mass Q-TOF mass detector (Agilent) eqipped with a HP5-MS fused silica capillary column (30 m, 0.25 mm i. d., 0.50 μm film). Instrumental parameters were (1) inlet pressure, 83.2 kPa, He 24.6 mL min−1, (2) injection volume, 2 μL, (3) transfer line, 250 °C, and (4) electron energy 70 eV. The GC was programmed for HRMS as follows: 5 min at 50 °C increasing at 5 °C min−1 to 320 °C, and operated in split mode (50:1, 60 s valve time). The carrier gas was He at 1 mL min−1.
7200 accurate mass q tof mass detector
The 7200 accurate-mass Q-TOF mass detector is a high-performance analytical instrument designed for precise mass measurements. It utilizes quadrupole time-of-flight (Q-TOF) technology to provide accurate mass data for a wide range of applications.
Lab products found in correlation
2 protocols using 7200 accurate mass q tof mass detector
GC-MS and HRMS Analysis of Terpene Cyclase Products
HRMS analyses were carried out with a 7890B gas chromatograph connected to a 7200 accurate-mass Q-TOF mass detector (Agilent) eqipped with a HP5-MS fused silica capillary column (30 m, 0.25 mm i. d., 0.50 μm film). Instrumental parameters were (1) inlet pressure, 83.2 kPa, He 24.6 mL min−1, (2) injection volume, 2 μL, (3) transfer line, 250 °C, and (4) electron energy 70 eV. The GC was programmed for HRMS as follows: 5 min at 50 °C increasing at 5 °C min−1 to 320 °C, and operated in split mode (50:1, 60 s valve time). The carrier gas was He at 1 mL min−1.
GC-MS and GC-HRMS Analytical Protocols
GC–HRMS analyses were carried out with a 7890B gas chromatograph connected to a 7200 accurate mass QTOF mass detector (Agilent) equipped with a HP5-MS fused silica capillary column (30 m, 0.25 mm i. d., 0.50 μm film). The instrumental parameters were (1) inlet pressure: 83.2 kPa, He 24.6 mL min−1, (2) injection volume: 2 μL, (3) split mode (10:1 to 50:1, 60 s valve time), (4) carrier gas: He 1 mL min−1, (5) transfer line: 250 °C, (6) electron energy 70 eV, (7) collision cell gas flow: 1 mL min−1 N2, (8) collision energy: 15 V, and (9) MS 1 scan resolution mode: narrow (m/z +/− 0.5). The temperature program of GC was set to: 5 min at 50 °C, then increasing by 10 °C min−1 to 320 °C, followed by 5 min at 320 °C.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!