Cobas e 411 auto analyser

Manufactured by Roche
Sourced in Germany

The Cobas e-411 is an automated immunoassay analyzer designed for in-vitro diagnostic testing. It is capable of performing various immunoassay tests, including those for hormones, tumor markers, and infectious diseases. The Cobas e-411 is intended to be used in clinical laboratory settings to aid in the diagnosis and monitoring of medical conditions.

Automatically generated - may contain errors

3 protocols using cobas e 411 auto analyser

1

Hormonal Assays in Clinical Lab

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum TSH, LH, FSH, prolactin and plasma ACTH estimation was done by electrochemiluminescent tracer-based immunometric assay (sandwich assay), while serum T4, cortisol, testosterone and estradiol were estimated by electrochemiluminescent tracer-based competitive immunoassay using Cobas e-411 auto-analyser (Roche Diagnostics, Mannheim, Germany). Serum GH and IGF-1 estimation was done by chemiluminescent tracer-based immunometric assay (sandwich assay) using Diasorin Liaison auto-analyser (Diasorin Inc., Stillwater, MN, USA). The internationally recommended recombinant 22 kDa GH standard (WHO 98/574) was adopted for the serum GH assay.[8 (link)]
+ Open protocol
+ Expand
2

Plasma Total 25-Hydroxyvitamin D Measurement

Check if the same lab product or an alternative is used in the 5 most similar protocols
The Bone Metabolism Group in the Faculty of Medicine, Dentistry and Health at Sheffield University measured plasma total 25-hydroxyvitamin D using an electrochemiluminescence binding method on a COBAS e 411auto analyser (Roche Diagnostics, Germany). The inter assay CV for total vitamin D was 5.7 %.
+ Open protocol
+ Expand
3

Serum AMH, FSH, and E2 Measurement

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood samples obtained by venipuncture were centrifuged, within 30 minutes from the collection, for 10 min at 3500 rpm, 4°C. Aliquots of each serum were frozen at −80°C and stored for subsequent assays of AMH, FSH and E2. To measure serum AMH levels, AMH-Gen II ELISA assay kit (Beckman Coulter) was used. The lowest detection limit of AMH is 0.08 ng/mL and the intra and interassay coefficients of variation below 3.4% and 4.0% respectively. The ECLIA method used to measure the levels of serum FSH and E2 by COBAS e411 auto-analyser (Roche Diagnostics). The lowest detection limit for FSH is 0.100 IU/L, with the intra- and interassay coefficients of variation below 2.6% and 3.5% respectively. The lowest detection limit for E2 is 18.4 pmol/L, with the intra- and interassay coefficients of variation of 2% and 3%, respectively.
Giving the poor reliability of the FSH value in presence of Estradiol levels greater than 70 pg/mL, women with basal E2 levels greater than this cut off were asked to come back at the beginning of the subsequent menstrual cycle, and their data were excluded from the analysis.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!