The largest database of trusted experimental protocols

7 protocols using avicularin

1

Analytical Standards for Phenolic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All solvents, reagents, and standards used were of analytical grade. Of these, 99.9% acetonitrile, 36.5–38% hydrochloric acid, >98% formic acid, cyanidin 3-O-galactoside chloride, cyanidin 3-O-arabinoside chloride, peonidin 3-O-galactoside chloride, and peonidin 3-O-arabinoside chloride were obtained from Sigma-Aldrich GmbH (Bethesda, MD, USA). Hyperoside, rutin, quercitrin, phloridzin, procyanidin B1, procyanidin B2, and chlorogenic acid standards were purchased from Extrasynthese (Genay, France), reynoutrin, (+)-catechin, and (−)-epicatechin were obtained from Sigma-Aldrich GmbH (Steinheim, Germany), and avicularin, procyanidin C1, and isoquercitrin were purchased from Chromadex (Santa Ana, CA, USA). Additionally, 96% ethanol was obtained from Stumbras AB (Kaunas, Lithuania), and 2,2-diphenyl-1-picrylhydrazyl (DPPH) was purchased from Vaseline-Fabrik Rhenania (Bonn, Germany). Purified deionized water used in the tests was prepared with the Milli-Q® (Millipore, Bedford, MA, USA) water purification system.
+ Open protocol
+ Expand
2

Antioxidant Capacity Evaluation Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Distilled water was purified using a Milli–Q system (Millipore, Bedford, MA, USA). Ethanol (96%) was obtained from Vilniaus degtine (Vilnius, Lithuania). Anhydrous acetic acid (99.8%), hydrochloric acid (37%) were purchased from Sigma–Aldrich (Buchs, Switzerland). The following reagents were used: 2,2′-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) diammonium salt (ABTS), 2,4,6-Tri-(2-pyridyl)-S-triazine (TPTZ), ferric chloride hexahydrate (FeCl3 × 6 H2O), sodium acetate (CH3COONa), 3-(2-pyridyl)-5,6-bis-(4-phenyl-sulfonic acid)-1,2,4-triazine (Ferrozine), obtained from Sigma-Aldrich (Buchs, Switzerland); potassium persulfate (K2S2O8), anhydrous ferrous chloride (FeCl2) from Alfa Aesar (Karlsruhe, Germany). The following standards were used: 6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid (Trolox), ethylene diamine tetra acetic acid (EDTA), quercetin, chlorogenic acid, cryptochlorogenic acid, ferulic acid, procyanidin A2 from Sigma–Aldrich (Buchs, Switzerland); arbutin, (+)-catechin, (−)-epicatechin from Fluka (Buchs, Switzerland); hyperoside, astragalin, rutin, isorhamnetin-3-O-glucoside, quercitrin from Extrasynthese (Genay, France); procyanidin C1, avicularin from ChromaDex (Irvine, CA, USA). All the reagents and standards were of analytical grade.
+ Open protocol
+ Expand
3

Phytochemical Analysis of Medicinal Plants

Check if the same lab product or an alternative is used in the 5 most similar protocols
All the standards, reagents, and solvents used through experiments were of analytical grade. Apigenin, diosmetin, hyperoside, rutin, quercitrin, luteolin-7-O-glucoside, Apigenin-7-O-glucoside, p-coumaric acid, caffeic acid, rosmarinic acid, and chlorogenic acid standards were purchased from Extrasynthese (Genay, France), and avicularin from Chromadex (Santa Ana, CA, USA). Acetic acid and acetonitrile were purchased from Sigma-Aldrich GmbH (Buchs, Switzerland), and ethanol from Vilniaus degtine, AB (Vilnius, Lithuania). Potassium persulfate, sodium acetate trihydrate, iron (III) chloride hexahydrate, and 2,4,6-tri(2-pyridyl)-S-triazine (TPTZ), 2,2-diphenyl-1-picrylhydrazyl (DPPH·) radical, and 2,2′-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid) (ABTS) were obtained from Sigma-Aldrich (Steinheim, Germany) and Trolox from Fluka Chemika (Buchs, Switzerland). Folin-Ciocalteu reagent, gallic acid monohydrate, aluminum chloride hexahydrate, sodium carbonate, hexamethylenetetramine, copper chloride, and neocuproine were purchased from Sigma-Aldrich GmbH (Buchs, Switzerland). Deionized water used in HPLC and for the samples preparation produced by the Crystal E high-performance liquid chromatography (HPLC, Adrona SIA, Riga, Latvia) water purification system.
+ Open protocol
+ Expand
4

Quantification of Polyphenolic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All solvents, reagents, and standards used were of analytical grade. Acetonitrile and acetic acid were obtained from Sigma-Aldrich GmbH (Buchs, Switzerland), ethanol was obtained from AB Stumbras (Kaunas, Lithuania), hyperoside, rutin, quercitrin, phloridzin, procyanidin B1, procyanidin B2 and chlorogenic acid standards were purchased from Extrasynthese (Genay, France), reynoutrin, (+)-catechin and (−)-epicatechin–from Sigma-Aldrich GmbH (Steinheim, Germany), and avicularin, procyanidin C1 and isoquercitrin–from Chromadex (Santa Ana, CA, USA). Purified deionized water used in the tests was prepared with the Milli-Q® (Millipore, Bedford, MA, USA) water purification system.
+ Open protocol
+ Expand
5

Analysis of Polyphenol Compounds in Food

Check if the same lab product or an alternative is used in the 5 most similar protocols
All solvents, reagents, and standards used were of analytical grade. Acetonitrile, acetic acid, D(+)-glucose monohydrate, hypromellose, AerosilTM 200, microcrystalline cellulose, silicon dioxide and starch were obtained from Sigma-Aldrich GmbH (Buchs, Switzerland), and ethanol was obtained from Stumbras AB (Kaunas, Lithuania). Hyperoside, rutin, quercitrin, phloridzin, procyanidin B1, procyanidin B2, and chlorogenic acid standards were purchased from Extrasynthese (Genay, France), reynoutrin, (+)-catechin and (−)-epicatechin were purchased from Sigma-Aldrich GmbH (Buchs, Switzerland), and avicularin, procyanidin C1, and isoquercitrin were purchased from Chromadex (Santa Ana, USA). In this study, we used deionized water produced by the Milli-Q® (Millipore, Bedford, MA, USA) water purification system.
+ Open protocol
+ Expand
6

Comprehensive Phytochemical Profiling and Antioxidant Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
All the solvents, reagents, and standards used were of analytical grade. Acetonitrile and acetic acid were obtained from Sigma-Aldrich GmbH (Buchs, Switzerland) and ethanol from Stumbras AB (Kaunas, Lithuania). Hyperoside, rutin, quercitrin, phloridzin, phloretin, caffeic acid, and chlorogenic acid standards were purchased from Extrasynthese (Genay, France), (+)-catechin and (–)-epicatechin from Fluka (Buchs, Switzerland) and avicularin and isoquercitrin from Chromadex (Santa Ana, USA). 1,1-Diphenyl-2-picrylhydrazyl (DPPH) radical, 2,2′-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid) (ABTS), potassium persulfate, sodium acetate trihydrate, iron (III) chloride hexahydrate, and 2,4,6-tripyridyl-s-triazine (TPTZ) were obtained from Sigma-Aldrich (Steinheim, Germany). Folin-Ciocalteu reagent, gallic acid monohydrate, sodium carbonate, aluminum chloride hexahydrate, and hexamethylenetetramine were purchased from Sigma-Aldrich GmbH (Buchs, Switzerland). Deionized water, produced by the Crystal E high-performance liquid chromatography (HPLC, Adrona SIA, Riga, Latvia) water purification system, was used.
+ Open protocol
+ Expand
7

Comprehensive Phytochemical Analysis and Antioxidant Evaluation

Check if the same lab product or an alternative is used in the 5 most similar protocols
All solvents, reagents, and standards used were of analytical grade. Acetonitrile and acetic acid were obtained from Sigma-Aldrich GmbH (Buchs, Switzerland) and ethanol from AB Stumbras (Kaunas, Lithuania). Hyperoside, rutin, quercitrin, phloridzin, procyanidin B1, procyanidin B2, and chlorogenic acid standards were purchased from Extrasynthese (Genay, France); reynoutrin, (+)-catechin, and (−)-epicatechin from Sigma-Aldrich GmbH (Steinheim, Germany); and avicularin, procyanidin C1, and isoquercitrin from Chromadex (Santa Ana, CA, USA). Purified deionized water used in the tests was prepared with the Milli-Q® (Millipore, Bedford, MA, USA) water purification system.
The reagents used in antioxidant activity assays—6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid (Trolox), 2,2-diphenyl-1-picrylhydrazyl (DPPH), and sodium acetate—were obtained from Scharlau (Barcelona, Spain), 2,4,6-tri(2-pyridyl)-s-triazine (TPTZ) was obtained from Carl Roth (Karlsruhe, Germany), and iron (III) chloride hexahydrate (FeCl3·6H2O) from Vaseline-Fabrik Rhenania (Bonn, Germany).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!