The largest database of trusted experimental protocols

4 protocols using 2 fluoroaniline

1

Synthesis of Functionalized Adamantanes

Check if the same lab product or an alternative is used in the 5 most similar protocols
Triethylamine (BioUltra ≥ 99.5%, CAS 121-44-8), 3-chloroaniline (99%, CAS 108-42-9), cyclohexyl isocyanate (98%, CAS 3173-53-3), phenyl isocyanate (98%, CAS 103-71-9) manufactured by Sigma-Aldrich (St. Louis, MO, USA) were used without purifying.
4-(Trifluoromethoxy) isocyanate (97%, CAS 35037-73-1), aniline (99+%, CAS 62-53-3), 2-fluoroaniline (99%, CAS 348-54-9), 3-fluoroaniline (98%, CAS 372-19-0), 4-fluoroaniline (99%, CAS 371-40-4) produced by the AlfaAesar (Ward Hill, MA, USA) were used without additional purification.
Diethyl ether was purified by well-known methods. trans-4-Amino-(cyclohexyloxy)benzoic acid 7a [2 (link)], 1,3-dehydroadamantane 2a [12 (link)], 1,3-dehydro-5,7-dimethyladamantane 2b [12 (link)], 2-(adamantane-1-yl)-2-phenylacetic acid ethyl ester 3a [15 (link)], 2-(adamantane-1-yl)-2-phenylacetic acid 4a, 1-(isocyanato(phenyl) methyl)adamantane 5a [10 (link)] were obtained by well-known methods.
+ Open protocol
+ Expand
2

Functionalization of Polymer-wrapped SWNTs

Check if the same lab product or an alternative is used in the 5 most similar protocols
Polymer-wrapped SWNTs were functionalized with a range of commercially available aryl compounds (2-iodoaniline, 2-bromoaniline, 2-fluoroaniline, 5-fluoro-2-iodoaniline, 2-iodophenol, thiophenol, indole; used as received from Sigma Aldrich, ≥97%). For a step-by-step protocol, refer to Supplementary Methods 1. Briefly, an appropriate amount of aryl reagent was dissolved in toluene to achieve a final reaction concentration of 29.30 mmol L−1. DMSO (anhydrous) and KOtBu (Sigma Aldrich, 98%) dissolved in THF (anhydrous) were added to this solution. Finally, an enriched SWNT dispersion in toluene was added to the mixture such that the SWNT concentration in the reaction mixture corresponded to an optical density of 0.3 cm−1 at the E11 transition. The final solvent composition was 83.3 : 8.3 : 8.3 vol-% toluene/DMSO/THF. Functionalization was performed in the dark or under illumination with UV-light (LED SOLIS-365C, Thorlabs, 365 nm, 1.9 mW mm−2) at room temperature. The reaction was stopped after a given time by vacuum filtration of the reaction mixture through a PTFE membrane filter (0.1 μm pore size). The collected SWNTs were washed with methanol and toluene to remove unreacted reagents and side products. The resulting filter cake was redispersed by bath sonication in toluene with fresh wrapping polymer for stabilization.
+ Open protocol
+ Expand
3

Analytical Comparison of Mass Spectrometry Techniques

Check if the same lab product or an alternative is used in the 5 most similar protocols
For our investigation, we used the same compounds as for Paper-LTPI28 (link) and in a comparison between Paper-LTPI, ESI and APCI27 (link): 3-aminophenol, 2-fluoroaniline, 3-fluoroaniline, 4-fluoroaniline, 2-methoxyaniline (o-anisidine), 3-methoxyaniline (m-anisidine), 4-methoxyaniline (p-anisidine), 2-nitroaniline, 3-nitroaniline, 4-nitroaniline, 3-methylaniline (m-toluidine), 3-aminoaniline (m-phenylenediamine), 4-aminoaniline (p-phenylenediamine), 2-aminobenzonitrile, 3-aminobenzonitrile and 4-aminobenzonitrile from Sigma Aldrich (Taufkirchen, Germany); 2-methylaniline (o-toluidine), 4-methylaniline (p-toluidine) from Fluka (Buchs, Switzerland) and aniline from Acros (Geel, Belgium). Acetonitrile (ACN, LC–MS grade) was from VWR (Dresden, Germany) and water (LC–MS grade) from BIOSOLVE (Valkenswaard, Netherlands). 2-aminoaniline (o-phenylenediamine), 2-aminopyridine, 3-aminopyridine, 4-aminopyridine, 2-aminophenol, 4-aminophenol, 2-aminobenzoic acid, 3-aminobenzoic acid, 4-aminobenzoic acid, sulfanilic acid and 4-chloroaniline were kindly provided by Prof. em. S. Berger (University of Leipzig, Germany).
+ Open protocol
+ Expand
4

Synthesis and Characterization of Substituted Anilines

Check if the same lab product or an alternative is used in the 5 most similar protocols
The analytical grades of ethyl 4-aminobenzoate, sodium nitrite (NaNO2), phenol, 1-bromohexane, 1,3-dicyclohexylcarbodiimide (DCC), 4-(N,N-dimethyl amino)pyridine (DMAP), 4-fluoro aniline, 2-fluoro aniline, 2-nitro aniline, 2-trifluoromethyl aniline, 2,4-dinitro aniline, potassium carbonate (K2CO3), sodium hydroxide (NaOH), potassium hydroxide (KOH), potassium iodide (KI) were procured from Sigma Aldrich and Spectrochem. For column chromatography silica gel 60-120 and neutral alumina were procured from Thomas baker. Acetone, hexane, ethyl acetate and dichloromethane were dried over phosphorus pentaoxide and calcium hydride, respectively. These solvents were distilled using standard methods when required for the experiment. Thin-layer chromatography (TLC) were performed on aluminium sheet precoated with silica gel-60 F254 (Merck). Infrared (IR) spectra were recorded using a PerkinElmer 1000 spectrometer. Proton nuclear magnetic resonance (1H NMR) spectra were recorded on a 400 MHz Bruker NMR spectrometer, using CDCl3 as a solvent and tetramethyl silane (TMS) as an internal standard.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!