The largest database of trusted experimental protocols

Hplc mals system

Manufactured by Shimadzu

The HPLC-MALS system is a laboratory instrument that combines high-performance liquid chromatography (HPLC) with multi-angle light scattering (MALS) detection. The core function of this system is to provide accurate measurements of the molecular weight and size distribution of macromolecules, such as proteins, polymers, and nanoparticles, as they elute from the HPLC separation.

Automatically generated - may contain errors

2 protocols using hplc mals system

1

SEC-MALS Analysis of Holo-MnmA Protein

Check if the same lab product or an alternative is used in the 5 most similar protocols
Size exclusion chromatography coupled with multi-angle light scattering (SEC-MALS) experiments were performed using an HPLC-MALS system (Shimadzu) equipped with light scattering detector (mini DAWN TREOS, Wyatt Technology), refractive index detector (Optilab T-rEX, Wyatt Technology) and UV detector (SPD-20A, Shimadzu). Holo-MnmA (100 μl at 2 mg ml−1) was injected on a Superdex 200 10/300 GL increase column (GE Healthcare) equilibrated in 50 mM Tris-HCl (pH 7.5), 200 mM NaCl buffer, in the presence or absence of DTT at a flow rate of 0.5 ml.min−1. Molar masses of proteins were calculated using the ASTRA 6.1 software (Wyatt Technology) using a refractive index increment (dn/dc) value of 0.183 ml g−1.
+ Open protocol
+ Expand
2

SEC-MALS Analysis of MmTtuI Protein

Check if the same lab product or an alternative is used in the 5 most similar protocols
Size exclusion chromatography coupled with multi-angle light scattering (SEC-MALS) experiments were performed using an HPLC-MALS system (Shimadzu) equipped with light scattering detector (mini DAWN TREOS, Wyatt Technology), refractive index detector (Optilab T-rEX, Wyatt Technology) and UV detector (SPD-20A, Shimadzu). As-purified MmTtuI (100 μl at 2 mg.ml−1) was injected on a Superdex 200 Increase 10/300 GL column (Cytiva) equilibrated in 50 mM HEPES pH 7.5, 200 mM NaCl, at a flow rate of 0.5 ml.min−1. Molar masses of proteins were calculated with the ASTRA 6.1 software (Wyatt Technology) using a refractive index increment (dn/dc) value of  0.183  ml.g−1.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!