4 protocols using vacuette fc mix tube

1

Electrochemical Glucose Biosensor Development

Check if the same lab product or an alternative is used in the 5 most similar protocols
d-(+)-Glucose (≥99.5%), phosphate-buffered
saline (PBS) tablets, silver nitrate (≥99.0%), gold(III) chloride
trihydrate (≥99.9%), sodium citrate dihydrate (≥99.0%), l-ascorbic acid (≥99.0%), potassium chloride (≥99.0%),
sulfuric acid (98%), methanol (≥99.9%), polyethylenimine (PEI,
MW ≈ 25000 by LS), Nafion solution (5 wt %), and 4-aminothiophenol
(4-ATP, 97%) were purchased from Sigma-Aldrich. Heme-containing, membrane-bound
bacterial glucose dehydrogenase (GDH) from Ewingella
americana
was purified and characterized according
to a previously published protocol.39 (link),45 (link) All aqueous
solutions were prepared in ultrapure water (resistivity of 18.2 MΩ
cm) purified by a Purelab Flex system (ELGA LabWater, High Wycombe,
UK). For whole blood analysis, blood samples from healthy donors were
collected in VACUETTE FC Mix tubes (Greiner Bio-One, Kremsmünster,
Austria). The tubes contain a mixture of additives Na2EDTA,
sodium fluoride, citric acid, and sodium citrate, which inhibits glycolysis
and prevents coagulation. Blood collection for analysis with the biosensors
was approved by the Swedish Ethical Board (approval number 2009/180).
+ Open protocol
+ Expand
2

D-Lactate Analysis from Blood Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood samples for D-lactate analysis were collected in 3-mL Vacuette® FC-mix tubes (Cat # 454513; Greiner Bio-One International GmbH), together with routine blood samples according to the protocol for blood sampling in the routine setting. The samples were drawn at admission after written and verbal consent were obtained according to the approval from the North Denmark Region Committee on Health Research Ethics. High-risk patients were included when AIN was suspected, and blood samples were collected in 3-mL Vacuette® FC-mix tubes after written and verbal consent were acquired and prior to surgery, in accordance with the above-mentioned approval.
+ Open protocol
+ Expand
3

Standardized Glucose Measurement Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
The third sample was collected into a VACUETTE® FC Mix Tube (Greiner Bio-One, containing a lyophilized mixture of Na2EDTA, sodium fluoride, citric acid, and sodium citrate) and was kept at room temperature until analysis within 3–4 h. The midwife delivered the samples to the laboratory directly after completion of the OGTT. Glucose was analyzed on a Cobas 8000 modular analyzer (Roche Diagnostics Ltd., Rotkreuz, Switzerland) by a hexokinase method (hereon referred to as CL) traceable to the glucose ID GC-MS. The method has shown a mean imprecision (CV%) of 1.0 and 1.1 at plasma glucose levels 3 mmol/L and 20 mmol/L, respectively (n = 50). The laboratory is accredited according to SS-EN ISO 15189 and participates in interlaboratory comparison schemes from Equalis (https://www.equalis.se/en/).
All women had their BMI calculated at their first antenatal visit. Clinical and sociodemographic details were recorded at the time of the diagnostic OGTT at the hospital.
+ Open protocol
+ Expand
4

Fasting Blood Sample Collection

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood samples were collected between 7.45 and 8.30 in the morning after 10 hours of fasting. Venous blood samples were collected with minimal stasis after 15 minutes rest in a supine position. The first 5 mL collected were discarded. The following 4 mL were collected in clot activator tubes (Becton-Dickinson, Plymouth, UK; BD Ref: 369032) and used for analyses of insulin and CRP in serum. Next, 3 mL were collected in trisodium citrate tubes (0.109 mol/L Na 3 Citrate, BD Ref: 363048) for analysis of vWF and t-PA:Ag. Finally, 3 mL were collected in EDTA-tubes (K 2 -EDTA: 5.4 mg, BD Ref: 367525) for IL-6 and ICAM-1, and 3 mL were collected in EDTA-tubes with citric acid and sodium fluoride (Vacuette FC Mix Tube, Greiner Bio-One, Frickenhausen, Germany, Ref: 454513) for plasma glucose measurements. Immediately after sampling, platelet poor plasma was prepared by centrifugation for 20 minutes at 2000 x g (20°C). Plasma and serum were transferred to aliquots, rapidly frozen and stored at -80 °C until testing.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!