The largest database of trusted experimental protocols

Caliper ivis lumina 2 imaging station

Manufactured by PerkinElmer
Sourced in United States

The Caliper IVIS Lumina II Imaging station is a bioluminescence and fluorescence imaging system designed for in vivo studies. The system is capable of capturing high-resolution images and quantifying signals from small animal models.

Automatically generated - may contain errors

2 protocols using caliper ivis lumina 2 imaging station

1

Arthritis Imaging with Antibody Conjugate

Check if the same lab product or an alternative is used in the 5 most similar protocols
Arthritis was induced exactly as described above. Once paw swelling was evident (arthritis score = ~ 2), 50 mg/kg F3 antibody conjugated to AF647 was administered via IP injection. Whole animal fluorescence was measured at various times using a Caliper IVIS Lumina II Imaging station (PerkinElmer, Santa Clara, CA) coupled to an ISOON5160 Andor Nikon camera equipped with Living Image Software Version 4.0 (Oxford Instruments, Concord, MA).
+ Open protocol
+ Expand
2

Fluorescent Dye Biodistribution in Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
Mice were injected via tail vein with 10 nmol of a fluorescent dye conjugate. Mice were sacrificed at 2, 4, and 6 h post-injection, and organs were removed (n = 1 per timepoint per conjugate for the initial UreterGlow-0, -3, -11, and -45 biodistribution studies and n = 3 per timepoint per conjugate for the UreterGlow-11, IR800CW, IR800BK, and ZW800-1 biodistribution studies). For urine analysis, mice were administered 10 nmol UreterGlow-11 via tail vein injection, sacrificed at various timepoints, and urine was removed from the bladder via syringe. The organs and urine were imaged using a Caliper IVIS Lumina II Imaging Station (PerkinElmer, Waltham, MA, USA) coupled with an ISOON5160 Andor Nikon camera equipped with Living Image Software Version 4.0 (PerkinElmer, Waltham, MA, USA). The settings were as follows: lamp level, high; excitation, 745 nm; emission, ICG; epi illumination; binning (M) 4; FOV, 12.5; f-stop, 4; acquisition time, 1 s.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!