The largest database of trusted experimental protocols

Pcdl manager software

Manufactured by Agilent Technologies

PCDL Manager software is a tool designed to create and manage Personal Compound Database and Libraries (PCDLs) for use with Agilent analytical instruments. The software allows users to build, edit, and maintain customized compound libraries, which can be used for identification and quantification purposes during data analysis.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using pcdl manager software

1

PCDL Construction Using Agilent Software

Check if the same lab product or an alternative is used in the 5 most similar protocols
A PCDL was constructed using Agilent PCDL Manager software (version B8.00). Either readily available or isolated and fully characterized in-house chemical compounds were utilized as reference standards to establish the PCDL. Data including the retention time, exact mass, and high-resolution MS fragmentation patterns were exported to the PCDL. Additional information, such as the molecular formula, compound name, and CAS number were assigned to each entry for constructing the PCDL.
+ Open protocol
+ Expand
2

Metabolic Flux Analysis Workflow

Check if the same lab product or an alternative is used in the 5 most similar protocols
Data processing for qualitative metabolic flux analysis was performed using VistaFlux software suite from Agilent Technologies. First, Pathways to PCDL software (version B.07.00, Agilent Technologies) and PCDL Manager software (version B.07.00, Agilent Technologies) was used to build a metabolite library for metabolites in both glycolysis and citric acid cycle. Then, acquired LC-MS raw data files (.d) were loaded into Profinder (version B.08.00, Agilent Technologies) for the extraction of metabolite isotopologues using the constructed metabolite library. The ion abundance criterion for data extraction was set as ‘use peak core area 20% of peak height’. The qualification parameters were set as: mass tolerance: ±15 ppm +2.00 mDa; retention time tolerance :±0.20 min; anchor ion height threshold: 250 counts; sum of ion heights threshold: 1000 counts; correlation coefficient threshold: 0.5. The final results were exported into a csv file for the subsequent comparative and statistical analyses.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!