The largest database of trusted experimental protocols

Combiflash rf 200

Manufactured by Teledyne
Sourced in United States

The CombiFlash Rf 200 is a flash chromatography system designed for purification of organic compounds. It provides automated control of mobile phase gradient, flow rate, and fraction collection to facilitate efficient separation and isolation of target analytes.

Automatically generated - may contain errors

41 protocols using combiflash rf 200

1

Synthesis and Characterization of Novel Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All commercial reagents and solvents were obtained from the commercial provider and used without further purification. Melting points (mp) were obtained with a MP90 melting point apparatus (Mettler-Toledo, Greifensee, Switzerland). 1H NMR and 13C NMR spectra were recorded on a Bruker Avance III 500 or II600 spectrometers (Varian, San Francisco, USA) in DMSO‑d6 with Me4Si as the internal standard. ESI high-resolution mass spectra (HRMS) were recorded on an Autospec Ultima-TOF spectrometer (Micromass UK Ltd., Manchester, U.K.). Flash chromatography over silica gel was performed on Combiflash Rf 200 (Teledyne, Nebraska, USA). Compounds 6a, 6b, 7ac, 7lo and 15b were synthesized and identified by mp or 1H NMR [[13] (link), [14] (link), [15] , [16] , [17] , [18] (link), [19] ].
+ Open protocol
+ Expand
2

Spectroscopic Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All commercial solvents and reagents were used without any purification. All reactions were monitored by thin layer chromatography (TLC) and visualized under UV light at 254 nm or iodine fumigation. Melting points (mp) were obtained with a MP90 melting point apparatus (Mettler-Toledo, Greifensee, Switzerland). 1H and 13C NMR spectral data were recorded with a Bruker Avance 400, 500 or 600 spectrometers (Varian, San Francisco, USA) in DMSO‑d6 or CDCl3 using tetramethylsilane (TMS) as the internal standard. High-resolution mass spectrometry (HRMS) was performed on an AutospecUitima-TOF mass spectrometer (Micromass UK Ltd., Manchester, U.K.). The flash column chromatograms were conducted on silica gel (200–300 mesh) using Combiflash Rf 200 (Teledyne, NE, USA).
+ Open protocol
+ Expand
3

Analytical Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All commercial chemicals were used as supplied unless otherwise indicated. Flash chromatography was performed on a Teledyne Combiflash RF-200 with RediSep columns (silica) and indicated mobile phase. 1H and 13C NMR spectra were recorded on a Varian 600 MHz or Bruker 400 spectrometer. Mass data were acquired using an Agilent 6230 TOF LC/MS spectrometer. All NMR and mass spectrometers are located in the shared instrument rooms at the Center for Drug Design, University of Minnesota.
+ Open protocol
+ Expand
4

Preparation and Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All commercial chemicals were used as supplied unless otherwise indicated. Dry solvents were either purchased (toluene and MeOH) or dispensed under argon from an anhydrous solvent system with two packed columns of neutral alumina or molecular sieves. Flash chromatography was performed on a Teledyne Combiflash RF-200 with RediSep columns (silica) and indicated mobile phase. All moisture sensitive reactions were performed under an inert atmosphere of ultrapure argon with oven-dried glassware. 1H and 13C NMR spectra were recorded on a Varian 600 MHz spectrometer. Mass data were acquired on an Agilent TOF II TOS/MS spectrometer capable of ESI and APCI ion sources. Analysis of sample purity was performed on a Varian Prepstar SD-1 HPLC system with a Phenomenex Gemini, 5 μm C18 column (250 mm × 4.6 mm). HPLC conditions: solvent A = H2O, solvent B = MeCN; flow rate = 1.0 mL/min; compounds were eluted with a gradient of 20% MeCN/H2O for 5 min then to 100% MeCN for 40 min. Purity was determined by total absorbance at 254 nm. All tested compounds have a purity ≥96.
+ Open protocol
+ Expand
5

Synthesis and Characterization of Anti-CVB3 Inhibitors

Check if the same lab product or an alternative is used in the 5 most similar protocols
Melting point (mp) was obtained with an MPA 100 OptiMelt automated melting point system (Stanford Research Systems, California, USA) and uncorrected. 1H NMR spectra was performed on a Varian Inova 400 MHz spectrometer (Varian, San Francisco, CA) or 500 MHz spectrometer (AV500-III, Brvker, Swiss), with Me4Si as internal standard. ESI high-resolution mass spectra (HRMS) were recorded on an AutospecUItima-TOF mass spectrometer (Micromass UK Ltd., Manchester, UK). Flash chromatography was performed on CombiflashRf 200 (Teledyne, Nebraska, USA), particle size 0.038 mm.
Compound 2 with purity over 98.5% was purchased from the Yanchi Dushun Biological and Chemical Co., Ltd. (Shanxi, China) and the Ningxia Zijinghua Pharmacy Co., Ltd. (Ningxia, China). Target compounds 9b-c, 9ek and 10bf were prepared as a family of anti-CVB3 inhibitors19 .
+ Open protocol
+ Expand
6

Purification and Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All commercial chemicals were used as supplied unless otherwise indicated. Dry solvents were either purchased (toluene and MeOH) or dispensed under argon from an anhydrous solvent system with two packed columns of neutral alumina or molecular sieves. Flash chromatography was performed on a Teledyne Combiflash RF-200 with RediSep columns (silica) and indicated mobile phase. All moisture sensitive reactions were performed under an inert atmosphere of ultra-pure argon with oven-dried glassware. 1H and 13C NMR spectra were recorded on a Varian 600 MHz spectrometer. Mass data were acquired on an Agilent TOF II TOS/MS spectrometer capable of ESI and APCI ion sources. Analysis of sample purity was performed on a Varian Prepstar SD-1 HPLC system with a Phenomenex Gemini, 5 micron C18 column (250mm × 4.6 mm). HPLC conditions: solvent A = H2O containing 0.1% TFA, solvent B = MeCN; flow rate = 1.0 mL/min; compounds were eluted with a gradient of 20% MeCN/H2O to 100% MeCN for 30 min. Purity was determined by total absorbance at 254 nm. All tested compounds have a purity ≥ 95%.
+ Open protocol
+ Expand
7

Synthesis of N-(4-Fluorophenyl)-4-Phenylthiazol-2-Amine

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 19

General Procedure.

2-Bromo-1-phenylethan-1-one (1.0 equivalent, 0.5 mmol) and 1-(4-fluorophenyl)thiourea (1.0 equivalent, 0.5 mmol) were premixed in 5 mL of ethanol. The mixture was pumped through a preheated glass microfluidic reactor (Syrris Asia Flow Chemistry Module) at a predetermined flow rate to have the desired residence time using Syrris Asia pump. The outcome was collected in a flask and concentrated under reduced pressure. The crude was dissolved in 10 mL ethyl acetate washed with 2×10 mL satd. NaHCO3. The organic phase was combined, dried MgSO4 and concentrated under reduced pressure. The crude product obtained was purified using prepacked silica cartridge on Teledyne CombiFlash Rf 200. Elution with 10:90 Hexaneethyl acetate afforded N-(4-fluorophenyl)-4-phenylthiazol-2-amine (MPA-1/RGCD 423F) in 98% yield. The same methodology was used to synthesize the other compounds disclosed herein.

Although the invention has been described with reference to the above examples, it will be understood that modifications and variations are encompassed within the spirit and scope of the invention. Accordingly, the invention is limited only by the following claims.

+ Open protocol
+ Expand
8

Spectroscopic Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Unless otherwise noted, all commercial reagents and solvents were obtained from the commercial provider and used without further purification. Melting points (mp) were obtained with CXM-300 melting point apparatus and are uncorrected. 1H NMR and 13C NMR spectra were recorded on a Bruker Avance 400 (400/101 MHz for 1H/13C) spectrometer or Bruker Avance III 500 (500/126 MHz for 1H/13C) spectrometer (Varian, San Francisco, USA) respectively, in DMSO-d6 with Me4Si as the internal standard. ESI high-resolution mass spectra (HRMS) were recorded on an AutospecUitima-TOF spectrometer (Micromass UK Ltd., Manchester, U.K.). Flash chromatography was performed on Combiflash Rf 200 (Teledyne, Nebraska, USA).
+ Open protocol
+ Expand
9

Analytical Methods for Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Antibodies against IκBα, IKKα, phospho-IKKα/β (Ser180/181), and glyceraldehyde-3-phosphate dehydrogenase (GADPH) were purchased from Cell Signaling Technology (Danvers, MA, USA). TNF-α was obtained from R&D Systems (Minneapolis, MN, USA). The p5×nuclear factor (NF)-κB-luciferase reporter plasmid, the pRL-TK plasmid and Dual-luciferase reporter assay system were from Promega (Madison, WI, USA).
Melting point (mp) was obtained with CXM-300 melting point apparatus and was uncorrected. The 1H-NMR spectra was performed on a Varian Inova 500 or 600 MHz spectrometer (Varian, San Francisco, CA, USA) and 13C-NMR on a Bruker Avance III 500 or 600 spectrometer in Dimethyl sulfoxide (DMSO)-d6, or CDCl3, with Me4Si as the internal standard. Electrospray ionization (ESI) high-resolution mass spectra (HRMS) were recorded on an Autospec UItima-TOF mass spectrometer (Micromass UK Ltd., Manchester, UK). Flash chromatography was performed on a Combiflash Rf 200 (Teledyne, NE, USA), particle size 0.038 mm.
+ Open protocol
+ Expand
10

Purification and Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All commercial chemicals were used as supplied unless otherwise indicated. Flash chromatography was performed on a Teledyne Combiflash RF-200 with RediSep columns (silica) and indicated mobile phase. All moisture sensitive reactions were performed under an inert atmosphere of ultrapure argon with oven-dried glassware. 1H and 13C NMR spectra were recorded on a Varian 600 MHz spectrometer. Mass data were acquired on an Agilent TOF II TOS/MS spectrometer capable of ESI and APCI ion sources. Analysis of sample purity was performed on a Varian Prepstar SD-1 HPLC system with a Phenomenex Gemini, 5 μm C18 column (250 mm × 4.6 mm). HPLC conditions: solvent A = H2O, solvent B = MeCN; flow rate =1.0 mL/min; compounds were eluted with a gradient of 10% MeCN/H2O for 0–5 min and to 80% MeCN/H2O from 5 to 30 min followed by 100% MeCN from 30 to 35 min and then 10% MeCN/H2O from 35 to 40 min. Purity was determined by total absorbance at 254 nm. All tested compounds have a purity ≥98%.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!