Pathromtin

Manufactured by Siemens
Sourced in Germany

Pathromtin is a lab equipment product designed for the measurement of activated partial thromboplastin time (aPTT), a test used to assess the intrinsic and common coagulation pathways. It is used in clinical laboratories for the evaluation of coagulation disorders and monitoring of anticoagulant therapy.

Automatically generated - may contain errors

3 protocols using pathromtin

1

Rivaroxaban Pharmacokinetics Evaluation

Check if the same lab product or an alternative is used in the 5 most similar protocols
The PT and aPTT were determined on an automated coagulation analyser (aPTT, pathromtin® SL; and PT, thromborel®; S BCSxp; Siemens) for patients receiving rivaroxaban. Rivaroxaban concentrations were also measured on the BCSxp, using a chromogenic assay calibrated for rivaroxaban (BIOPHEN® DiXa-I; CoaChrom Diagnostica, Neuville-sur-Oise, France).
+ Open protocol
+ Expand
2

Coagulation Assays Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
APTT (seconds), international normalized ratio (INR) (ratio, [no unity]), fibrinogen (µmol/L), and antithrombin (IU/ml) assays were performed on the ACL Top 500 (Instrumentation Laboratory, Milano, Italy) with dedicated reagents for INR, fibrinogen, and antithrombin, and the reagent Pathromtin (Siemens, Erlangen, Germany) for APTT.
+ Open protocol
+ Expand
3

Blood Coagulation Biomarker Measurement

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood samples were collected from the antecubital vein into 0.109 mol/l trisodium citrate tubes (Vacutainer, Becton Dickinson, New Jersey, USA) in the morning, after an overnight fasting. Plasma samples were obtained by centrifuging blood at 2000 Â g for 15 min at room temperature for von Willebrand factor (vWF)-ag, fibrinogen, FVIII and at 4 8C only for PAI-1 evaluation. Complete blood cell count was performed by using the Sysmex XE-2100 hematology analyzer (Sysmex, Kobe, Japan). Fibrinogen was assessed by Clauss clotting method (Siemens, Marburg, Germany). Plasma PAI-1 antigen levels were measured with commercially available ELISA kits (PAI-1 Actibind ELISA, Technoclone, Wien, Austria). FVIII activity was determined by a coagulation-based assay, with deficient plasma in the presence of Pathromtin (Coagulation Factor VIII, Siemens); vWF antigen levels were detected by a turbidimetric assay (vWFAg, Siemens).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!