Gc ms equipment

Manufactured by Agilent Technologies
Sourced in United States

The GC-MS equipment is a powerful analytical instrument that combines gas chromatography (GC) and mass spectrometry (MS) technologies. It is designed to separate, identify, and quantify a wide range of chemical compounds with high accuracy and sensitivity.

Automatically generated - may contain errors

3 protocols using gc ms equipment

1

Characterization of Pollutant Adsorption in Pellets

Check if the same lab product or an alternative is used in the 5 most similar protocols
To confirm the composition of each pellet, a FTIR spectrometer equipped with an Attenuated Total Reflection module (ATR-FTIR), model Cary 630 (Agilent Technologies®, Santa Clara, CA, USA), was used.
The determination of the color and the identification of the YI value of each pellet was carried out using a colorimeter, video spectrocomparator VSC5000 (Foster Freeman®, Evesham, UK).
To evaluate the adsorption rate of pollutants in pellets based on their degradation state, POPs were analyzed using GC-MS equipment (Agilent Technologies®, Santa Clara, CA, USA), model 7820A and 5977B MSD, with an HP-5MS Ultra Inert 19091S-433UI column, following a methodology for multiresidual analysis [47 ]. An orbital shaker was used for pellet conditioning (Supelco®, Darmstadt, Germany).
+ Open protocol
+ Expand
2

GC-MS Analysis of Volatile Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Samples were analyzed with a GC-MS equipment from Agilent Technologies (Santa Clara, CA, USA). This was composed of a 7890 gas chromatograph and a 5977B HES mass spectrometric detector equipped with a high-efficiency ion source. To carry out the chromatographic separations a Chrompark (Varian, Middelburg, The Netherlands) CP-WAX 57 CB (50 m × 0,25 mm i.d., 0.2 µm film thickness) fused silica capillary column was employed. The oven temperature was programmed as follows: the initial temperature was 40 °C; after 5 min it was raised a rate of 3.5 °C/min to 120 °C, and finally a rate of 5 °C/min to 215 °C and held for 10 min. The split–splitless injection port was operated in splitless mode at 270 °C for 1 min. The mass spectra were recorded by electronic impact (EI) ionization at 70 eV with a temperature of 230 °C in the ion source and 150 °C in the mass quadrupole. The mass range analyzed was from 35 to 300 amu (atomic mass units).
+ Open protocol
+ Expand
3

Fatty Acid Extraction and Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Total FA were extracted from approximately 100 mg of cells. After incubation with virus for 48 h, cells were washed 3 times with PBS and then scraped off the culture dish using a 2-mL aliquot of 2.5% (vol/vol) vitriol:methanol. Then, GMEC were transferred into a clean tube according to protocols described previously (Folch et al., 1957) . Methylated lipid samples were analyzed using a GC-MS equipment (Agilent Technologies, Santa Clara, CA) installed with an HP-5 column (60 m × 0.25 mm i.d. × 0.25 μm film thickness) following a published procedure from our laboratory (Wang et al., 2012) . The relative proportions of FA were calculated as percentages of the total peak areas that could be detected.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.