Wizard2 link 2480 automatic gamma counter

Manufactured by PerkinElmer
Sourced in United Kingdom

The Wizard2 2480 automatic gamma counter is a laboratory instrument designed for the detection and measurement of gamma radiation. It is capable of accurately counting and quantifying radioactive samples. The device provides consistent and reliable performance for a wide range of applications in research and clinical settings.

Automatically generated - may contain errors

4 protocols using wizard2 link 2480 automatic gamma counter

1

In Vivo Biodistribution of Radiolabeled HDL

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood radioactivity half-life was determined by serial blood draws from the tail vein at 1, 5, 30, 60 and 120 minutes and 6, 24 and 48 hours after 89Zr-19F-HDL injection. Blood was weighed and counted using a Wizard2 (link) 2480 automatic gamma counter (Perkin Elmer). After scans were completed, animals were sacrificed and perfused, and tissues (brain, heart, lungs, aorta, spleen, liver, kidneys, skeletal muscle and bone marrow) were collected, blotted and weighed in pre-weighed tubes. Radioactivity content was measured by gamma counting, and tissue radioactivity concentration was calculated and expressed as % injected dose per gram (%ID/g) or normalized by activity found in muscle tissue.
+ Open protocol
+ Expand
2

In Vivo Liposome Biodistribution

Check if the same lab product or an alternative is used in the 5 most similar protocols
To perform the pharmacokinetic analysis, blood was withdrawn from the marginal ear vein at 30 min, 24, 48, 72 and 120 h post injection of liposomes. Next, samples were weighed and radioactivity concentration was measured on a Wizard2 (link) 2480 automatic gamma counter (Perkin Elmer, Waltham, MA). For assessment of percent injected dose (%ID), blood volume was estimated using the formula (0.6*bodyweight + 0.77) as previously described32 (link). Following the final in vivo imaging session and 30 min prior to sacrifice animals were injected with 0.5% of 5 mL of Evans Blue (Sigma-Aldrich, St. Louis, MO) in PBS. Afterwards rabbits were sacrificed using an overdose of pentobarbital and saline perfused. Next, pieces of organs were harvested, weighted and counted using a Wizard2 (link) 2480 automatic gamma counter for assessment of 89Zr-liposome biodistribution.
+ Open protocol
+ Expand
3

Radiotracer Biodistribution in Tumor-Bearing Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
HCT116 tumour-bearing NCr female nude mice (as prepared for the metabolite analysis procedure) were injected via the lateral tail vein with the appropriate radiotracer in sterile saline solution (∼10 MBq). At 15 or 60 minutes post-injection, the mice were sacrificed by exsanguination via cardiac puncture under general anaesthesia (isoflurane inhalation). The appropriate tissues were then excised, weighed and the radioactivity was measured using a 2480 WIZARD2 (link) automatic gamma counter (PerkinElmer, UK). Each experiment was performed in triplicate and data were expressed as the mean percentage of the injected dose per gram of tissue (%ID g–1) ± SD.
+ Open protocol
+ Expand
4

Quantitative Analysis of [18F]3 in Rat Plasma

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood metabolite studies were performed by the procedure reported in previous literature.17 (link) Blood samples were taken from rats (n = 2) at 10, 30, and 60 min after [18F]3 injection. Each blood sample was centrifuged for 3 min to separate plasma and blood coagulants. The plasma (0.3 ml) was retrieved, and 0.3 ml of acetonitrile was added to the plasma. The suspended solution was vortexed, and centrifuged for 3 min to precipitate protein and to obtain protein-free plasma as supernatant. The resulting supernatant was divided 2 parts. One part was used for measuring the total radioactivity and another part (0.3 ml) was loaded to a Strata-X C18 cartridge (500 mg, Phenomenex Inc.) that had been purged with water. A series of elutions were performed using using 0.1% TFA/water and 0.1% TFA/acetonitrile in quantities: 95:5, 90:10, 85:15, 80:20, 70:30, 60:40, 30:70, 100% of 0.1% TFA/acetonitrile at a volume of 4 mL. The eluted fractions were collected in eight test tubes. A control experiment by injection of a small amount of [18F]3 onto a test cartridge elution described above indicated that the parent [18F]3 was collected in the seventh test tube exclusively. The radioactivities were measured using a 2480 Wizard2 (link) Automatic Gamma Counter (PerkinElmer Inc., Waltham, MA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!