The largest database of trusted experimental protocols

Pes membrane filter

Manufactured by Agilent Technologies

The PES membrane filter is a laboratory filtration device made of polyethersulfone (PES) material. Its core function is to separate and retain particles, cells, or other suspended matter from liquid samples during the filtration process. The PES membrane provides a physical barrier for efficient removal of these components from the sample solution.

Automatically generated - may contain errors

2 protocols using pes membrane filter

1

Sulfated Galactoglucomannan: Molecular Weight Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
The weight-average molecular weight Mw, number-average molecular weight Mn, and polydispersity of the sulfated GGM (SGGM) samples were determined by gel permeation chromatography (GPC) using an Agilent 1260 Infinity II Multi-Detector GPC/SEC system with two detectors: a refractometer (RI) and a viscometer (VS). The separation was made on two Agilent PL aquagel-OH columns. The samples were eluted with an eluent composed of 0.1 M NaNO3 and 0.25 g/L of NaN3 as a stabilizer (pH 7) at a flow rate 1 mL/min and a sample volume of 100 μL. Polyethylene glycol standards (Agilent, Santa Clara, CA, USA) were used to calibrate the columns. All the samples were dissolved overnight in the mobile phase (1–5 mg/mL) and then filtered through a 0.22-μm Agilent PES membrane filter to remove impurities. The data were collected and processed using the Agilent GPC/SEC MDS software.
+ Open protocol
+ Expand
2

Globin Chain Separation by HPLC

Check if the same lab product or an alternative is used in the 5 most similar protocols
Globin chain separation was achieved by high-performance liquid chromatography (HPLC) using a LithoCART 250-4 column (VWR) and an Agilent 1260 infinity II HPLC system with acetonitrile-methanol gradients41 (link) Lysates were prepared from baboon peripheral blood by freeze-thaw lysis, clarified by centrifugation (12 000 rotation per minutes for 15 minutes), and filtered through a 22 μm Agilent PES membrane filter before injection.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!