The largest database of trusted experimental protocols

Ml064292

Manufactured by Mlbio
Sourced in China

The Ml064292 is a laboratory instrument designed for precise liquid handling. It features automated pipetting and dispensing functions to facilitate accurate and repeatable liquid transfers. The device is intended for use in various laboratory applications that require precise liquid management.

Automatically generated - may contain errors

2 protocols using ml064292

1

Serum and Tissue Biomarker Analysis in Rats

Check if the same lab product or an alternative is used in the 5 most similar protocols
The serum levels of insulin (kt30476, MSKbio, Wuhan, China), TC (kt30156, MSKbio, Wuhan, China), TGs (kt50023, MSKbio, Wuhan, China), LDL-C (kt25323, MSKbio, Wuhan, China) and LPS (E-EL-R0589c, Elabscience, Wuhan, China) as well as tumour necrosis factor-alpha (TNF-α, ml002859, mlbio, Shanghai, China), interleukin 6 (IL-6, ml064292, mlbio, Shanghai, China) and IL-1β (PI303, Beyotime, Beijing, China) levels in liver tissue were detected by specific ELISA kits. Briefly, rat serum was added into the enzyme-labelled plates and incubated at 37 °C for 90 min. Then, the fluid in the plates was discarded, and 100 μL biotinylated antibody was added into the plates. After 60 min incubation at 37 °C, the plates were washed by the buffer solution thrice, added with the enzyme-conjugated working solution and incubated at 37 °C for 30 min. Subsequently, the plates were supplemented with the substrate Reagent and incubated at 37 °C for 15 min. Following these, H2SO4 (2 M, 50 μL) was added to each well to terminate the reaction. Ultimately, the optical density at 450 nm was recorded under a microplate reader (ELx808, BioTek, Winooski, VT).
Later, homeostasis model assessment-insulin resistance (HOMA-IR) was calculated according to this formula (Jia N et al. 2018 ):
HOMAIR=[fasting blood glucose (FBG, mmol/L) × fasting insulin level (FINS, mUI/L)/22.5].
+ Open protocol
+ Expand
2

Serum HO-1, IL-6, and IL-10 Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
The blood collected from the vacuum sampling without anticoagulant was placed with 30min at room temperature, then the serum was obtained by 3000xg centrifugation 10min at 4 °C. The concentrations of HO-1 (ml003108,Mlbio, Shanghai, China), IL-6 (ml064292,Mlbio, Shanghai, China) and IL-10 (ml002813,Mlbio, Shanghai, China) were detected by ELISA kit. The operation was carried out strictly according to the instructions of the kit, and the absorbance value was detected by enzyme labeling instrument (SynergyH1,BioTek,USA), and the standard curve was drawn.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer