The largest database of trusted experimental protocols

Ytterbium solution standard for aas

Manufactured by Merck Group

Ytterbium solution standard for AAS is a laboratory product that provides a reference solution for the calibration and verification of atomic absorption spectrometry (AAS) equipment. It contains a known concentration of the element ytterbium, which is used to ensure the accuracy and precision of AAS measurements.

Automatically generated - may contain errors

2 protocols using ytterbium solution standard for aas

1

Zinc Content Quantification in Cellular Extracts

Check if the same lab product or an alternative is used in the 5 most similar protocols
Shimadzu ICP 9000 (with Mini plasma Torch in axial reading mode) was used to measure the zinc content. Standard solution for AAS (Sigma Aldrich) was used to generate the calibration curve between 10 to 500 µg/L in pure water with 1% of HNO3 (Fluka). Samples were routinely incubated in HNO3 10% ON at RT. Briefly, 500 µl of each cytosolic crude extract was incubated with 90 µl of HNO3 65% ON at RT. The sample was centrifuged at 13,000 rpm for 5 min. Before to be measured pure water was added to the supernatant extemporaneously to obtain a final volume of 7 ml. Ytterbium solution standard for AAS (Sigma Aldrich) was used as an internal standard to prevent calibration drift and fluidic perturbation. The result was express in µg/L [Zn] per mg of protein.
+ Open protocol
+ Expand
2

Quantifying Zinc in Cytosolic Extracts

Check if the same lab product or an alternative is used in the 5 most similar protocols
Shimadzu ICP 9000 (with Mini plasma Torch in axial reading mode) was used to measure the zinc content. Standard solution for AAS (Sigma Aldrich) was used to generate the calibration curve between 10 to 500 µg/L in pure water with 1% of HNO3 (Fluka). Samples were routinely incubated in HNO3 10% ON at RT. Briefly, 500µl of each cytosolic crude extract was incubated with 90µl of HNO3 65% ON at RT. The sample was centrifuged at 13,000 rpm for 5 min. Before to be measured pure water was added to the supernatant extemporaneously to obtain a final volume of 7 ml. Ytterbium solution standard for AAS (Sigma Aldrich) was used as an internal standard to prevent calibration drift and fluidic perturbation. The result was express in µg/L [Zn] per mg of protein.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!