The largest database of trusted experimental protocols

St5020 cv5030 coverslipper

Manufactured by Leica
Sourced in United States, France

The ST5020 and CV5030 are automated coverslipper instruments designed for laboratory use. The ST5020 is a slide coverslipper that automatically applies coverslips to prepared slides. The CV5030 is a coverslipper that automatically applies coverslips to microscope slides. Both products are intended to streamline the slide preparation process in laboratory settings.

Automatically generated - may contain errors

2 protocols using st5020 cv5030 coverslipper

1

Penile Smooth Muscle and Collagen Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
The fixed proximal portion of the penis of 6 of 13 sham_SHR and 8 of 12 ESWT_SHR was paraffin embedded and 5-μm sections were performed using a microtome (RM 2245; Leica Biosystems, Nanterre, France). The sections were positioned on SuperFrost plus glass slides (Thermo Fisher Scientific, Waltham, MA, USA), dried, and stained for evaluation of smooth muscle/collagen ratio with Masson’s trichrome method using an automated multistainer (ST5020 &CV5030 Coverslipper; Leica Biosystems). The acquisition of slides images was then performed using Aperio AT2 - Scanner for On-Screen Diagnosis (Leica Biosystems). The percent of smooth muscle and the percent of collagen were computed in the total area of CC from each section by a blinded experimenter using the positive pixel count algorithm (Leica Biosystems). For each animal, 4 transverse sections of penis were stained and analyzed and a mean smooth muscle/collagen ratio was determined.
+ Open protocol
+ Expand
2

Quantitative Histomorphometric Analysis of Rat Bladder

Check if the same lab product or an alternative is used in the 5 most similar protocols
The rats were euthanized and the bladder was harvested, paraffin embedded and 5-μm sections were performed using a microtome (RM 2245®, Leica Biosystems, France). The sections were stained with hematoxylin-eosin using an automated multistainer (ST5020® &CV5030 Coverslipper® Leica Biosystems, France) for evaluation of detrusor wall area, the detrusor being sandwiched between the mucosa and adventitia. The acquisition of slides images was then performed using Aperio AT2 - Scanner for On-Screen Diagnosis® (Leica Biosystems, France). Then images were analyzed with NIS Elements Software (NIS elements, Nikon, France) to compute the detrusor wall area from each section by a blinded experimenter. For each animal, 4 transverse sections were analyzed and a mean area of sections per animal was then determined.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!