Manufactured by B&W Tek
Sourced in Germany

The BWF-1-785/55371 is a compact and portable Raman spectrometer designed for laboratory use. It features a 785 nm laser source and a spectrograph with a 55371 grating. The device is intended for spectroscopic analysis applications.

Automatically generated - may contain errors

2 protocols using bwf 1 785 55371

1

Multispectral SWIR Fluorescence Imaging

Check if the same lab product or an alternative is used in the 5 most similar protocols
A multispectral SWIR fluorescence imaging system was designed and constructed (Fig. 2). Briefly, tissue is illuminated by a 785-nm fiber-coupled laser (BWF-1-785/55371, B&W Tek) dispersed onto the sample using a ground glass diffuser (DG10-220-MD, Thorlabs, Germany). SWIR fluorescence emission from the sample is collected by a highly sensitive InGaAs camera [ QE>80% 950 to 1600 nm, NIRvana 640, Teledyne Princeton Instruments Fig. 2(b)] coupled to a SWIR lens ( f=16  mm , F/1.4, Navitar, Canada). Fluorescence light is sequentially filtered using a six-position filter wheel (LTFW6, Thorlabs, Germany) through six long-pass filters with cut-off wavelengths of 850, 950, 1050, 1150, 1250, and 1350 nm [FELH series, Thorlabs, Germany, Fig. 2(b)]. The system was mounted inside a light-tight enclosure to remove background light. The camera was cooled to 80°C to reduce thermal noise.
+ Open protocol
+ Expand
2

Novel Near-Infrared Fluorescence Imaging

Check if the same lab product or an alternative is used in the 5 most similar protocols
A novel system was designed and constructed (Fig. 1). Briefly, tissue is illuminated by a 785-nm fiber-coupled laser (BWF-1–785/55371, B&W Tek) dispersed onto the sample using a ground glass diffuser (DG10–220-MD, Thorlabs). SWIR fluorescence emission from the sample is collected by a highly sensitive InGaAs camera (QE > 80% 950–1,600 nm, NIRvana 640, Teledyne Princeton Instruments) coupled to a SWIR lens (f = 16 mm, F/1.4, Navitar). Fluorescence light is sequentially filtered using a 6-position filter wheel (LTFW6, Thorlabs) through 6 long-pass filters with cut-off wavelengths of 850, 950, 1,050, 1,150, 1,250, and 1,350 nm (FELH series, Thorlabs). The system was mounted inside a light-tight enclosure to remove background light. The camera was cooled to −80°C to reduce thermal noise. Images were captured using LightField (Teledyne Princeton Instruments) and saved as 16-bit TIFs for analysis.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!