The largest database of trusted experimental protocols

Peg 700

Manufactured by Merck Group

PEG 700 is a polyethylene glycol compound with an average molecular weight of 700 g/mol. It is a clear, viscous liquid that is soluble in water and organic solvents. PEG 700 is commonly used as a solvent, plasticizer, and surfactant in various industrial and pharmaceutical applications.

Automatically generated - may contain errors

4 protocols using peg 700

1

Magnetically Controlled Microrobot Fabrication

Check if the same lab product or an alternative is used in the 5 most similar protocols
The photoresist utilized to fabricate the microrobot consisted of a 468 mg mixture of 47 vol% PEG-700 (Poly(ethylene glycol) diacrylate with a molecular weight of 700, Sigma-Aldrich), 28 vol% PEG-250 (Poly(ethylene glycol) diacrylate with a molecular weight of 250, Sigma-Aldrich), 14 vol% buffer solution (Tris-EDTA buffer solution, Sigma-Aldrich) and 11 vol% photoinitiator (2-hydrox-2-methylpropiophenone, Sigma-Aldrich). 7.4 mg of superparamagnetic microparticles (Amino paramagnetic particles 1–2 micron, CAT# 18879, Polysciences, Inc.) and 8.5 μL rhodamine solution (Rhodamin B, Sigma-Aldrich) were added to the photoresist mixture to allow for magnetic control and to enable fluorescent imaging of the microrobots. In the viscous mixing experiment, a droplet (5 μL) of glycerol (Sigma-Aldrich) fluorescent dyed with Rhodamin B (Sigma-Aldrich) is used.
+ Open protocol
+ Expand
2

Photosensitive Polymer Microfabrication

Check if the same lab product or an alternative is used in the 5 most similar protocols
The utilized photosensitive mixture is composed of a synthetic polymer (Polyethylene glycol with a molecular weight of 700, PEG 700, Sigma-Aldrich) and a photo-initiator (2-hydroxy-2-methyl-1-phenyl-propan-1-one, Darocur 1173, Sigma-Aldrich) at a ratio of 5:1. The photo-initiator will trigger the crosslink of PEG 700 when exposed to UV light. One droplet (~30 μL) of Rhodamine B solution (Sigma-Aldrich) is added to the mixture (5 mL) to align the mask, and one droplet (~30 μL) of blue food dye is added to the solution to visualize the fabricated micromachines.
+ Open protocol
+ Expand
3

Photocrosslinkable Microswimmer Fabrication

Check if the same lab product or an alternative is used in the 5 most similar protocols
The microswimmers were fabricated using a mixture of photo-crosslinkable
polyethylene glycol (PEG) and a photo-initiator. The mixture consisted of 40%
(v/v) PEG diacrylate with a molecular weight of 700 (PEG700, from
Sigma-Aldrich), 25% (v/v) PEG with a molecular weight of 258 (PEG 258, from
Sigma-Aldrich), 15% (v/v) photo-initiator
2-Hydroxy-2-methyl-1-phenyl-propan-1-one (Darocur 1173, from Ciba), 15% (v/v) TE
buffer (100 TE, from OmniPur), and 5% (w/v) fluorescein.
+ Open protocol
+ Expand
4

Photosensitive PEG Hydrogels for Microrobotics

Check if the same lab product or an alternative is used in the 5 most similar protocols
The photosensitive polymer mixture used in this project consists of photo-cross-linkable polyethylene glycols (PEGs) and a photo-initiator. The ratios of each component in the mixture were: 50% (v/v) PEG diacrylate with a molecular weight of 700 (PEG 700, Sigma-Aldrich), 30% (v/v) PEG diacrylate with a molecular weight of 258 (PEG 258, Sigma-Aldrich), 15% (v/v) TE buffer (100 TE, Sigma-Aldrich), and 5% (v/v) photo-initiator 2-hydroxy-2-methyl-1-phenyl-propan-1-one (Darocur 1173, Sigma-Aldrich) as photo-initiator. In addition, a droplet (~50 μl) each of fluorescent Rhodamine B (Sigma-Aldrich) and food dye were added to facilitate the focusing of the photomask and to achieve better contrast for the microrobots suspended in DI water.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!