The largest database of trusted experimental protocols

Ftir fir spectrometer model frontier

Manufactured by PerkinElmer

The FRONTIER FTIR/FIR Spectrometer is a versatile instrument designed for spectroscopic analysis. It combines Fourier Transform Infrared (FTIR) and Far-Infrared (FIR) spectroscopy capabilities in a single device. The spectrometer is capable of detecting and analyzing a wide range of molecular vibrations, enabling users to identify and characterize a variety of samples.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using ftir fir spectrometer model frontier

1

Multimodal Characterization of Chemical Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
1H NMR studies
were carried out on a Bruker Avance III 400 spectrometer, and standard
references were used: tetramethylsilane (TMS) (δ 1H (400 MHz) = 0 and δ 13C (100 MHz) = 0). 7Li, 23Na, and 39K NMR experiments were carried
out at 298 K using NaCl, KCl, and LiCl 0.5 M in D2O as
an external reference, respectively. The parameters for the three
metals were: 7Li recorded at 155.50 MHz with a spectral
sweep (sw) of 24,000 Hz; 23Na at 105.86 MHz, sw of 20,000
Hz; and 39K at 18.67 MHz, sw 20,000 Hz. IR spectra were
recorded on a PerkinElmer FTIR/FIR Spectrometer model FRONTIER using
attenuated total reflection (ATR) and KBr pellet techniques. Mass
spectrometry was conducted on an Agilent 6100 LC/MS using the ESI+ mode. UV–vis measurements were performed on an Agilent
8435 (Agilent Technologies) diode array with a quartz cell 1 cm optical
path. Fluorescence studies were carried out on a Lambda LB-50 with
a xenon lamp, quantifications consisting of 1–1000 light pulses
per measurement, depending on the required reading quality and speed,
and with a glass cell with 1 cm light path. Melting points were recorded
on a Büchi melting point B-545 apparatus.
+ Open protocol
+ Expand
2

Comprehensive Spectroscopic Analysis Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
1H NMR studies were carried
out on a Bruker AVANCE III 400 spectrometer, and standard references
were used: tetramethylsilane (TMS) (δ 1H (400 MHz)
= 0 and δ 13C (100 MHz) = 0). IR spectra were recorded
on a PerkinElmer FT-IR/FIR Spectrometer model FRONTIER instrument
using attenuated total reflection (ATR). Mass spectrometry was conducted
on an Agilent 6100 LC/MS using the ESI+ mode. The titrations
by UV–vis were performed on an Agilent 8435 ultraviolet–visible
spectrophotometer (Agilent Technologies) equipped with a deuterium
and halogen lamp, using a spectral range of 187 to 1100 nm and quartz
cells with a 1 cm optical path length. Fluorescence studies were carried
out on a Lambda LB-50 with a xenon lamp, with quantifications consisting
of 1–1000 light pulses per measurement, depending on the required
reading quality and speed, and with a glass cell with a 1 cm light
path. Melting points were recorded on a Büchi melting point
B-545 apparatus.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!