The largest database of trusted experimental protocols

2 protocols using c19 0 coa

1

Quantitative Analysis of LCA-CoA

Check if the same lab product or an alternative is used in the 5 most similar protocols
LCA-CoA concentration was measured according to Blachnio-Zabielska et al. [41 (link)]. Briefly, malonyl-CoA as well as LCA-CoA were extracted according to Minkler et al. [42 (link)]. Prior to the extraction procedure, a known amount of C15:0-CoA, 16:0(d4) CoA, C17-CoA, C19:0-CoA, C21:0-CoA, C23:0:-CoA and 24:0(d4) CoA (Avanti Polar Lipids, Alabaster, AL, USA) was added as an internal standard. The molecules (C14:0-CoA, C16:0-CoA, C16:1-CoA, C18:2-CoA, C18:1-CoA, C18:0-CoA, C20:0-CoA, C22:0-CoA, C24:1-CoA and C24:0-CoA, Avanti Polar Lipids, Alabaster, AL, USA) were separated on a reverse-phase Agilent ZORBAX Extend-C18 Column, 2.1 × 150 mm, using a binary gradient with ammonium hydroxide (NH4OH) in water and NH4OH in ACN. The LCA-CoA concentration was quantified using multiple reaction monitoring (MRM) on a triple quadrupole mass spectrometer (Sciex QTRAP 6500+, AB Sciex Germany GmbH, Darmstadt, Germany) in positive electrospray ionization (ESI) mode against the concentration standard curves prepared for each compound.
+ Open protocol
+ Expand
2

Targeted Lipidomics for Malonyl-CoA and LCA-CoA

Check if the same lab product or an alternative is used in the 5 most similar protocols
Malonyl-CoA and LCA-CoA were extracted according to Minkler et al. [29 (link)] and their concentrations were measured according to Blachnio-Zabielska et al. [30 (link)]. Before extraction, the internal standard: C15:0-CoA, 16:0(d4)CoA, C17-CoA, C19:0-CoA, C21:0-CoA, C23:0-CoA and 24:0-(d4)-CoA (Avanti Polar Lipids, Alabaster, AL, USA) was added to all samples. The molecules were separated on a reversed-phase Agilent ZORBAX Extend-C18 column, 2.1 × 150 mm, using a binary gradient with ammonium hydroxide (NH4OH) in water and NH4OH in ACN. The concentration of LCA-CoA was quantified using multiple reaction monitoring (MRM) on a triple quadrupole mass spectrometer (Sciex QTRAP 6500+, AB Sciex Germany GmbH, Darmstadt, Germany) in positive electrospray ionization (ESI) mode against the concentration standard curves prepared for each compound (C14:0-CoA, C16:0-CoA, C16:1-CoA, C18:2-CoA, C18:1-CoA, C18:0-CoA, C20:0-CoA, C22:0-CoA, C24:1-CoA and C24:0-CoA, Avanti Polar Lipids, Alabaster, AL, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!