The largest database of trusted experimental protocols

Anti cd14 buv737

Manufactured by BD
Sourced in United States

Anti-CD14-BUV737 is a fluorochrome-conjugated antibody that binds to the CD14 cell surface marker. CD14 is a glycosylphosphatidylinositol (GPI)-anchored protein expressed on the surface of monocytes and macrophages. The BUV737 fluorochrome is used for flow cytometry analysis.

Automatically generated - may contain errors

2 protocols using anti cd14 buv737

1

NK Cell Activation Assay Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cells were stained for surface markers for 20 min at room temperature in PBS (Sigma). Extracellular antibodies used were as follows: LIVE/DEAD Fixable Near-IR (Thermo Fischer Scientific; L10119), Anti-CD3-BUV737 (BD Biosciences; 612750), Anti-CD14-BUV737 (BD Biosciences; 612763); Anti-CD14-BUV395 (BD Biosciences; 563561); Anti-CD19-BUV737 (BD Biosciences; 564303), Anti-CD19-BUV395 (BD Biosciences; 563549); Anti-CD56-PerCP-Cy5.5 (Biolegend; 304626), Anti-CD16-Pe-Cy7 (Biolegend; 302016), Anti-CD107a-BV510 (Biolegend; 328632), Anti-CD69-BV650 (Biolegend; 310934). Samples were then washed and fixed using 4% formaldehyde or BD Cytofix/Cytoperm Kit (BD biosciences) according to manufacturer’s directions. Flow cytometry analysis was performed on a LSRII instrument (BD Biosciences). A total of 50,000 to 250,000 events were acquired and analyzed using FlowJo software. The analysis was performed on gated cells that fell within the lymphocyte population, stained as live cells using Live/Dead stain. Cells were then gated for negative CD3/CD14/CD19 expression to exclude other cell populations, and NK cells were identified using CD56/CD16 gating strategy. Gating strategies are shown in Supplementary Figure S1. Within the NK cell population, we analyzed expression of CD107a and CD69 for each sample compared to their corresponding unstimulated control.
+ Open protocol
+ Expand
2

Multiparametric Immune Cell Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
The following antibodies were used for flow cytometric analyses: anti-CD45-BV786 (Cat-No. 563716, BD Biosciences, Franklin Lakes, NJ, USA), anti-HLADR-BUV395 (Cat-No. 565972, BD Biosciences, Franklin Lakes, NJ, USA), anti-CD11c-BV711 (Cat-No. 563130, BD Biosciences, Franklin Lakes, NJ, USA), anti-CD14-BUV737 (Cat-No. 612763, BD Biosciences, Franklin Lakes, NJ, USA), anti-CD16-FITC (Cat-No. 406555, BD Biosciences, Franklin Lakes, NJ, USA), anti-CD86-BV510 (Cat-No. 563460, BD Biosciences, Franklin Lakes, NJ, USA), anti-PD-L1-BV650 (Cat-No. 563740, BD Biosciences, Franklin Lakes, NJ, USA). Data were acquired on a Celesta (BD Biosciences, Franklin Lakes, NJ, USA) flow cytometer using the BD FACSDiVa™ software v8.0.1.1 and analyzed with FlowJo 10.3.0 (FlowJo LLC, Ashland, OR, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!