The largest database of trusted experimental protocols

Mc8 equipment

Manufactured by Physiologic Instruments

The MC8 is a multi-channel data acquisition system designed for physiological research applications. It features eight independent input channels with adjustable gain and filtering options. The system is capable of recording a variety of signals, including electrophysiological data, from various sensors and transducers.

Automatically generated - may contain errors

2 protocols using mc8 equipment

1

CFTR-Mediated Ion Transport Measurements

Check if the same lab product or an alternative is used in the 5 most similar protocols
CFBE or HBE cells expressing WT- or ΔF508-CFTR were grown to confluence on permeable filters at an air-liquid interface and mounted in modified Ussing chambers. Isc measurements were obtained under voltage clamp conditions using MC8 equipment and P2300 Ussing chambers (Physiologic Instruments) as previously described [51 (link),52 (link),103 (link)]. Cells were equilibrated for 5–10 min in regular Ringer solution (115 mM NaCl, 25 mM NaHCO3, 2.4 mM KH2PO4, 1.24 mM K2HPO4, 1.2 mM CaCl2, 1.2 mM MgCl2, 10 mM D-glucose, pH 7.4). In some measurements, this was followed by the exchange of low chloride Ringer (115 mM NaCl reduced to 1.2 mM NaCl and 10 mM D-glucose replaced with 115 mM Na-gluconate) to the apical surface. After addition of the sodium channel inhibitor amiloride (100 μM), the CFTR agonists Frk (10 μM) and gen (50 μM) were sequentially added, followed by inhibitor172 (10 μM) at the conclusion of each experiment, in order to specifically inhibit CFTR activity. Changes in CFTR-mediated ion transport were calculated using the highest current value for each sample after achievement of a stable plateau for several minutes.
+ Open protocol
+ Expand
2

Tracheal Ion Transport Measurements

Check if the same lab product or an alternative is used in the 5 most similar protocols
Tracheas were excised, sectioned into 3–4 segments, and opened longitudinally along the dorsal surface. Segments were mounted as flat sheets in modified Ussing chambers (area ∼0.031 cm2) maintained at 37°C and bubbled vigorously with 95% O2∶5% CO2.
ISC measurements were performed under voltage clamp conductions using MC8 equipment and P2300 Ussing chambers (Physiologic Instruments, San Diego, CA). Tissue segments were equilibrated for 10 minutes in regular Ringer solution that contained (in mM) 120 NaCl, 25 NaHCO3, 3.33 KH2PO4, 0.83 K2HPO4, 1.2 CaCl2, 1.2 MgCl2, and 10 mannitol to establish a baseline and then tested by one of the following experimental protocols:
Changes in ISC attributable to ion transport agonists and inhibitors were calculated following achievement of a stable plateau for several minutes. ATP-sensitive ISC was measured as the highest current value for each sample [21] (link).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!