Model rtesp

Manufactured by Veeco

The RTESP is a lab equipment product from Veeco. It is designed for real-time spectroscopic ellipsometry measurements. The core function of the RTESP is to provide accurate and reliable data on the optical properties and thickness of thin films.

Automatically generated - may contain errors

4 protocols using model rtesp

1

Atomic Force Microscopy of Graphene Flakes

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 12

Atomic Force Microscopy (AFM) Characterization of Graphene Flakes.

For graphene flake characterization, a sample of graphene/EC dispersion in ethanol was deposited onto Si/SiO2 for AFM characterization. Prior to sample deposition, Si/SiO2 wafers were immersed in 2.5 mM 3-aminopropyl triethoxysilane (Aldrich, 99%) in 2-propanol (Macron Chemicals, 99.5%) for 30 minutes, after which they were rinsed with 2-propanol and blown dry under a stream of N2. A diluted graphene dispersion was dropcast onto the wafers and left for 10 minutes, after which it was blown dry with N2 and rinsed with 2-propanol. To remove ethyl cellulose and residual 3-aminopropyl triethoxysilane, the samples were annealed at 400° C. in a tube furnace for 30 minutes. AFM images were obtained using a Bruker ICON PT AFM System in tapping mode with a Veeco Model RTESP (MPP-11100-10) cantilever. The images were collected with 2 μm×2 μm scans, and particle characteristics were determined using Nanoscope Analysis software. Flake thickness was determined from line scans, and flake area was measured automatically using the software. Flake thickness was measured for 355 flakes, and flake area was measured for 216 flakes. (See FIGS. 9A-C.)

+ Open protocol
+ Expand
2

Characterization of Graphene Flakes by AFM

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 12

Atomic Force Microscopy (AFM) Characterization of Graphene Flakes.

For graphene flake characterization, a sample of graphene/EC dispersion in ethanol was deposited onto Si/SiO2 for AFM characterization. Prior to sample deposition, Si/SiO2 wafers were immersed in 2.5 mM 3-aminopropyl triethoxysilane (Aldrich, 99%) in 2-propanol (Macron Chemicals, 99.5%) for 30 minutes, after which they were rinsed with 2-propanol and blown dry under a stream of N2. A diluted graphene dispersion was dropcast onto the wafers and left for 10 minutes, after which it was blown dry with N2 and rinsed with 2-propanol. To remove ethyl cellulose and residual 3-aminopropyl triethoxysilane, the samples were annealed at 400° C. in a tube furnace for 30 minutes. AFM images were obtained using a Bruker ICON PT AFM System in tapping mode with a Veeco Model RTESP (MPP-11100-10) cantilever. The images were collected with 2 μm×2 μm scans, and particle characteristics were determined using Nanoscope Analysis software. Flake thickness was determined from line scans, and flake area was measured automatically using the software. Flake thickness was measured for 355 flakes, and flake area was measured for 216 flakes. (See FIGS. 9A-C.)

+ Open protocol
+ Expand
3

Characterization of Graphene Flakes by AFM

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 12

Atomic Force Microscopy (AFM) Characterization of Graphene Flakes.

For graphene flake characterization, a sample of graphene/EC dispersion in ethanol was deposited onto Si/SiO2 for AFM characterization. Prior to sample deposition, Si/SiO2 wafers were immersed in 2.5 mM 3-aminopropyl triethoxysilane (Aldrich, 99%) in 2-propanol (Macron Chemicals, 99.5%) for 30 minutes, after which they were rinsed with 2-propanol and blown dry under a stream of N2. A diluted graphene dispersion was dropcast onto the wafers and left for 10 minutes, after which it was blown dry with N2 and rinsed with 2-propanol. To remove ethyl cellulose and residual 3-aminopropyl triethoxysilane, the samples were annealed at 400° C. in a tube furnace for 30 minutes. AFM images were obtained using a Bruker ICON PT AFM System in tapping mode with a Veeco Model RTESP (MPP-11100-10) cantilever. The images were collected with 2 μm×2 μm scans, and particle characteristics were determined using Nanoscope Analysis software. Flake thickness was determined from line scans, and flake area was measured automatically using the software. Flake thickness was measured for 355 flakes, and flake area was measured for 216 flakes. (See FIGS. 9A-C.)

+ Open protocol
+ Expand
4

Characterization of Graphene Flakes by AFM

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 12

Atomic Force Microscopy (AFM) Characterization of Graphene Flakes.

For graphene flake characterization, a sample of graphene/EC dispersion in ethanol was deposited onto Si/SiO2 for AFM characterization. Prior to sample deposition, Si/SiO2 wafers were immersed in 2.5 mM 3-aminopropyl triethoxysilane (Aldrich, 99%) in 2-propanol (Macron Chemicals, 99.5%) for 30 minutes, after which they were rinsed with 2-propanol and blown dry under a stream of N2. A diluted graphene dispersion was dropcast onto the wafers and left for 10 minutes, after which it was blown dry with N2 and rinsed with 2-propanol. To remove ethyl cellulose and residual 3-aminopropyl triethoxysilane, the samples were annealed at 400° C. in a tube furnace for 30 minutes. AFM images were obtained using a Bruker ICON PT AFM System in tapping mode with a Veeco Model RTESP (MPP-11100-10) cantilever. The images were collected with 2 μm×2 μm scans, and particle characteristics were determined using Nanoscope Analysis software. Flake thickness was determined from line scans, and flake area was measured automatically using the software. Flake thickness was measured for 355 flakes, and flake area was measured for 216 flakes. (See FIGS. 9A-C.)

+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!