The largest database of trusted experimental protocols

Esi tof ms

Manufactured by Agilent Technologies

The ESI-TOF-MS is a mass spectrometry instrument that utilizes electrospray ionization (ESI) and time-of-flight (TOF) mass analysis technology. It is designed to accurately measure the mass-to-charge ratio of ionized molecules in a sample.

Automatically generated - may contain errors

5 protocols using esi tof ms

1

Spectroscopic Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
UV-vis spectra were collected by Shimadzu UV-2550 Spectrophotometer. Mass spectra were recorded on an Agilent Technologies ESI-TOF-MS. Thin-layer chromatography (TLC) was carried out with silicycle pre-coated silica gel plates. NMR spectra were recorded at room temperature on a Bruker AV-500 spectrometer in chloroform-d3 with TMS and chloroform signal as an internal reference.
+ Open protocol
+ Expand
2

Negative Ion Mode ESI-MS of Crystals

Check if the same lab product or an alternative is used in the 5 most similar protocols
Negative ion mode ESI-MS of the DMF solution of crystals of 1 was measured on an LTQ linear ion trap spectrometer by Agilent Technologies ESI-TOF-MS (6230). The spray voltage was 5.48 kV and the capillary temperature was kept at 300 °C. The capillary voltage was 30 V. The samples were prepared inside a glovebox and very rapidly transferred to the spectrometer in an airtight syringe by direct infusion with a Harvard syringe pump at 0.2 mL/min.
+ Open protocol
+ Expand
3

ESI-MS Analysis of Cu4Pb22 Complex

Check if the same lab product or an alternative is used in the 5 most similar protocols
Negative
ion mode ESI-MS of the DMF solutions of a single crystal of [Cu4Pb22]4– were measured on an LTQ
linear ion trap spectrometer from Agilent Technologies, ESI-TOF-MS
(6230). The spray voltage was 5.48 kV, and the capillary temperature
was maintained at 300 °C. The capillary voltage was 30 V. The
samples were made up inside a glovebox under a nitrogen atmosphere
and rapidly transferred to the spectrometer in an airtight syringe
by direct infusion with a Harvard syringe pump at 0.2 mL/min.
+ Open protocol
+ Expand
4

Comprehensive Characterization of Materials

Check if the same lab product or an alternative is used in the 5 most similar protocols
UV-Vis absorption spectra was recorded on a Shimadzu UV-2550 Spectrophotometer. Mass spectrum was recorded on an Agilent Technologies ESI-TOF-MS. Fourier-transform infrared spectroscopy (FT-IR) spectra were collected in the range of 4000–400 cm−1 with a Bruker FT-IR spectrometer. Nuclear magnetic resonance (NMR) data were collected on a JEOL ECS-400 spectrometer. X-ray photoelectron spectroscopy (XPS) studies were performed on PHI Quantum-2000 XPS. The sample was put under UHV to reach the10−8 Pa range. The non-monochromatized Al Kα source was used at 10 kV and 10 mA. All binding energies were calibrated using the C (1s) carbon peak (284.6 eV), which was applied as an internal standard. High resolution narrow-scan spectra were recorded with the electron pass energy of 50 eV and takeoff angle of 55° to achieve the maximum spectral resolution.
+ Open protocol
+ Expand
5

Negative Ion Mode ESI-MS Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Negative ion mode ESI-MS of the DMF solutions of crystals of 1′ and 2′ were measured on an LTQ linear ion trap spectrometer by Agilent Technologies ESI-TOF-MS (6230). The spray voltage was 5.48 kV and the capillary temperature was kept at 300 °C. The capillary voltage was 30 V. The samples were made up inside a glovebox under a nitrogen atmosphere and rapidly transferred to the spectrometer in an airtight syringe by direct infusion with a Harvard syringe pump at 0.2 mL/min.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!