Magnetom verio 3t system

Manufactured by Siemens
Sourced in Germany

The Magnetom Verio 3T system is a magnetic resonance imaging (MRI) scanner developed by Siemens. It operates at a magnetic field strength of 3 Tesla, providing high-quality imaging capabilities. The core function of the Magnetom Verio 3T is to generate detailed images of the human body for medical diagnosis and research purposes.

Automatically generated - may contain errors

Lab products found in correlation

5 protocols using magnetom verio 3t system

1

Neonatal Brain MRI Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
MRI was performed on a Siemens Magnetom Verio 3T system (Siemens Healthcare Gmbh, Erlangen, Germany) using a 12-channel matrix phased array head coil. All infants were scanned axially to acquire: 3D T1-weighted MPRAGE volume (1 mm3 resolution), T2-weighted STIR (0.9 mm3 resolution), T2-weighted FLAIR (1 mm3 resolution), and diffusion MRI (dMRI) (11 T2- and 64 diffusion encoding direction (b = 750 s/mm2) single-shot spin-echo echo planar imaging (EPI) volumes with 2 mm isotropic voxels, TE = 106 ms and TR = 7300 ms. Images were reported by a pediatric radiologist with experience in neonatal MRI (AQ), according to the system described by Woodward et al. (Woodward et al., 2006 (link)), with the modification for grey matter scores proposed by Leuchter et al. (Leuchter et al., 2014 (link)).
MRI was performed in the neonatal period during natural sleep, without sedation. A neonatologist was present for the duration of each MRI scan, and the infant had continuous oxygen saturation and heart rate monitoring. For acoustic protection, flexible earplugs and neonatal earmuffs (MiniMuffs, Nat's Medical Inc., CA) were used.
+ Open protocol
+ Expand
2

3T MRI Protocol for Gadolinium-Enhanced Imaging

Check if the same lab product or an alternative is used in the 5 most similar protocols
MRI examinations were performed with patients in the prone position using a Magnetom Verio 3T system (Siemens Healthcare, Erlangen, Germany) in a dedicated eight-channel phase-array coil. We obtained MR images using the following sequences in Table 1. The images were acquired before and after the injection of gadolinium DTPA (0.1 mmol/kg Gadovist; Bayer Schering Pharma, Berlin, Germany).
+ Open protocol
+ Expand
3

Diffusion-Weighted MRI Preprocessing Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Diffusion-weighted MRI (dMRI) data were obtained using a MAGNETOM Verio 3 T system (Siemens AG, Erlangen, Germany). For each participant, 31 volume images were acquired with a single-shot diffusion-weighted echo planar imaging sequence. The data set consisted of 30 volume images with high diffusion weighting (b value = 1,000 s/mm2) applied along respective diffusion gradient encoding directions and one volume image with no diffusion weighting (b value = 0 s/mm2). Each volume image included 2.0 mm thick 75 axial slices of a 114 × 114 matrix with 2.0 mm × 2.0 mm in-plane resolution.
The acquired raw dMRI data was preprocessed using the tools in FSL 5.0.9 (http://fsl.fmrib.ox.ac.uk/fsl/). Each participant’s 31 volume images were realigned to the volume image with no diffusion weighting to correct for eddy current-induced distortions and head motion, and then non-brain tissue was deleted from the whole head in the realigned volume images.
+ Open protocol
+ Expand
4

Multiparametric MRI Examination of Patients

Check if the same lab product or an alternative is used in the 5 most similar protocols
MRI examinations were performed for patients in prone position using a Magnetom Verio 3 T system (Siemens Healthcare, Erlangen, Germany) and a dedicated eight-channel phase-array coil. Images were obtained using the following sequences: (1) axial turbo spin-echo T2-weighted imaging (T2WI) with TR/TE of 4530/93 msec, flip angle of 80°, field of view (FOV) 320 × 320 mm2, matrix size of 576 × 403, slice thickness of 4 mm, and acquisition time of 2 min 28 sec; (2) pre-contrast T1-weighted three-dimensional (3D) volumetric interpolated breath-hold examinations (3D VIBE) with TR/TE of 2.7/0.8 msec, FOV of 320 × 320 mm2, matrix size of 256 × 192, slice thickness of 2 mm with various flip angles (2°, 6°, 9°, 12°, 15°), and acquisition time of 2 min 15 sec to determine tissue T1 relaxation time prior to the arrival of contrast agent; (3) dynamic contrast-enhanced axial T1-weighted imaging (T1WI) with fat suppression with TR/TE of 2.5/0.8 msec, flip angle of 10°, slice thickness of 2.0 mm, and acquisition time of 5 min 30 sec (temporal resolution 6 sec) following an intravenous bolus injection of 0.1 mmol/kg gadobutol (Gadovist, Schering, Berlin, Germany) followed by a 20 ml saline flush; (4) delayed axialT1-weighted 3D VIBE with TR/TE of 4.4/1.7 msec, flip angle of 10°, slice thickness of 1.2 mm, FOV of 340 mm, and matrix size of 448 × 358 to evaluate the overall extent of tumor.
+ Open protocol
+ Expand
5

Diffusion Tensor Imaging of ALS Subtypes

Check if the same lab product or an alternative is used in the 5 most similar protocols
Twenty-one patients (9 pALS, 7 ALS-EX, 5 ALS-NECI) underwent DTI on a Siemens Magnetom Verio 3T system with a standard 32-channel phased array imaging head coil (Siemens Medical Systems, Erlangen, Germany). Scans were acquired by single-shot, spin-echo, echo-planar imaging with a twice-refocused echo-sequence (FOV = 256 × 256 mm2, 128 × 128 acquisition matrix, slice thickness = 2 mm, TR = 12,700 ms, TE = 81 ms, receiver bandwidth = 1628 Hz/pixel, echo spacing = 0.72 ms, 1 non diffusion-weighted scan, 30 diffusion gradient directions, b = 1000 s/mm2, 2 averages).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!