The largest database of trusted experimental protocols

4 protocols using alt and ast detection kits

1

Quantitative Assay for Liver Enzymes

Check if the same lab product or an alternative is used in the 5 most similar protocols
The levels of ALT and AST were calculated using ALT and AST detection kits (Nanjing Jiancheng Bio Institute), according to the manufacturers' protocol. The absorbance was measured at a wavelength of 510 nm with a microplate reader. Cellular ALT and AST contents are expressed U/mg cellular protein with pyruvic acid sodium to generate the standard curve.
+ Open protocol
+ Expand
2

Hepatoprotective Effects of MF

Check if the same lab product or an alternative is used in the 5 most similar protocols
MF (C19H18O11, FW = 422.34, purity ≥ 95%) was purchased from Nanjing ZeLang Medical Technology Co. Ltd. (Nanjing, China). LPS (Escherichia coli, 0111: B4), D-GalN, and ZnPP IX were obtained from Sigma (St. Louis, MO, USA). ALT and AST detection kits were purchased from Nanjing Jiancheng Bioengineering Institute (Nanjing, China). The bicinchoninic acid (BCA) protein assay kit was purchased from Pierce (Rockford, IL, USA). Trizol reagent was purchased from Invitrogen (Grand Island, NY, USA). AMV transcriptase, RNasin, SYBR green PCR Master Mix, and the Dual-Luciferase Reporter Assay kit were obtained from Promega (Madison, WI, USA). The tumor necrosis factor (TNF)-α ELISA kit was obtained from Bender MedSystems (Vienna, Austria). Rabbit HO-1 antibody was obtained from Abcam (Cambridge, MA, UK), rabbit β-actin antibody was purchased from Cell Signaling Technology (Boston, MA, USA), and the rat anti-mouse TLR4/MD-2 complex and rat IgG2a isotype control PE were obtained from eBioscience (San Diego, CA, USA). Lipofectamine 2000 was obtained from Invitrogen (Carlsbad, CA, USA).
+ Open protocol
+ Expand
3

Angiotensin II-Induced Fibrosis Pathway

Check if the same lab product or an alternative is used in the 5 most similar protocols
Ang II was provided by Sigma (St. Louis, MO, USA). MD2 (no. ab24182), TLR4 (no. ab22048), α-SMA (no. ab5694), ICAM-1 (no. ab171123), and VCAM-1 (no. ab134047) antibodies were purchased from Abcam (Cambridge, MA, USA). GAPDH (no. sc-293335) and β-actin (sc-47778) antibodies were obtained from Santa Cruz Technology (Santa Cruz, CA, USA). ERK (9101S), p-ERK (9102S), and IκB-α (4812S) were purchased from Cell Signaling Technology (Danvers, MA, USA). ALT and AST detection kits were purchased from Nanjing Jiancheng Bioengineering Institute (Nanjing, China). L6H21 was synthesized and structurally identified using MS and 1H NMR analyses, as described in our previous report [22 (link)]. For in vivo studies, L6H21 was dissolved in 1% CMC-Na, and 1% CMC-Na also acted as the vehicle control.
+ Open protocol
+ Expand
4

Measuring Liver Function Markers

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum ALT and AST levels, which are markers of liver function or injury, were determined using ALT and AST detection kits (Nanjing Jiancheng Bioengineering Institute, Nanjing, China) according to the manufacturer’s protocol.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!