The largest database of trusted experimental protocols

Wtc 015s5 sized exclusion column

Manufactured by Wyatt Technology

The WTC-015S5 sized exclusion column is a laboratory instrument designed for size-exclusion chromatography. It is used to separate molecules based on their size and shape, allowing for the analysis and purification of complex mixtures. The column's core function is to facilitate the size-based separation of sample components, providing insights into the molecular composition and properties of the analyzed substances.

Automatically generated - may contain errors

2 protocols using wtc 015s5 sized exclusion column

1

SEC-MALS Analysis of PML RING Mutants

Check if the same lab product or an alternative is used in the 5 most similar protocols
The purified PML RING1–119 and mutants were subjected to gel filtration analysis (S100 column, GE Healthcare). The elution peaks, as monitored by UV absorption at 280 nm, were pooled separately and chosen for size exclusion chromatography-multi-angle light scattering (SEC-MALS) characterization, respectively. In brief, the purified protein samples were concentrated and analyzed using a WTC-015S5 sized exclusion column (Wyatt Technology) which was connected to a 1260 infinity liquid chromatography system (Agilent Technology) equipped with inline DAWN HELEOS-II MALS and Optilab rEX differential refractive index detectors (Wyatt Technology). For each sample, a 40 μl injection volume and 0.5 ml min−1 flow rate were applied. Data were recorded and processed using ASTRA VI software (Wyatt Technology).
+ Open protocol
+ Expand
2

Gel Filtration Analysis of SafDAA-dsc and Mutants

Check if the same lab product or an alternative is used in the 5 most similar protocols
SafDAA-dsc and mutants were subjected to gel filtration analysis using a WTC-015S5 sized exclusion column (Wyatt Technology). The elution of each sample was analyzed by a 1260 infinity liquid chromatography system (Agilent Technology) linked with inline DAWN HELEOS-II MALS and Optilab rEX differential refractive index detectors (Wyatt Technology). For each run, a 40-μl sample (2.5 mg/ml) was injected. The sample was eluted at a flow-rate of 0.5 ml/min for SafDAA-dsc and mutants. Data were recorded and analyzed using ASTRA VI software (Wyatt Technology).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!