The largest database of trusted experimental protocols

Thermo scientific spectrometer helios episilon

Manufactured by Thermo Fisher Scientific

The Thermo Scientific Spectrometer Helios Epsilon is a high-performance UV-Vis spectrophotometer designed for accurate and reliable absorbance measurements. It features a compact and ergonomic design, a range of scanning modes, and advanced data analysis capabilities.

Automatically generated - may contain errors

2 protocols using thermo scientific spectrometer helios episilon

1

Bradford Assay for Protein Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
The protein concentrations of the samples were determined using the Bradford Assay—Sigma [22 ]. Bovine serum albumin (BSA- Fisher Scientific) standards of known protein concentration varying from 0 to 2 mg/ml were added to Bradford reagent in disposable cuvettes (Fisher Scientific) and the absorbance was measured spectrophotometrically at 595nm in a Thermo Scientific Spectrometer Helios Episilon (Fisher Scientific). The absorbance of the known protein standards were plotted using a linear regression. The mitochondrial fractions were diluted 1 μl in 100 μl Tris Buffer and added to Bradford reagent before the absorbance was measured. The absorbance was plotted against the BSA standard curve to determine the estimated protein concentration (mg/ml).
+ Open protocol
+ Expand
2

Protein Quantification using Bradford Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
The protein concentrations of the samples were determined using the Bradford Assay - Sigma [64 ]. Bovine serum albumin (BSA- Fisher Scientific) standards of known protein concentration varying from 0 to 2mg/ml were added to Bradford reagent in disposable cuvettes (Fisher Scientific) and the absorbance was measured spectrophotometrically at 595 nm in a Thermo Scientific Spectrometer Helios Episilon (Fisher Scientific). The absorbance of the known protein standards was plotted using linear regression. The mitochondrial fractions were diluted 1 μl in 100 μl Tris Buffer and added to Bradford reagent before the absorbance was measured. The absorbance was plotted against the BSA standard curve to determine the estimated protein concentration (mg/ml).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.